100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Product Overview

The Honeywell TK-FTEB01 functions as a high-availability Fault Tolerant Ethernet (FTE) network bridge for Experion LS and PKS Series-A automation platforms. This communications gateway creates a deterministic, high-speed data link between control chassis components and the supervisory process network to ensure continuous, real-time I/O synchronization. Plant managers install this critical module to eliminate communication vulnerabilities, allowing control data to flow without interruption even during severe hardware or cable malfunctions. We supply this product as a 100% brand new, factory-original unit in its original box to guarantee optimal field reliability and extended service life.

Technical Specifications

Parameter Specification Details
Manufacturer Honeywell
Model Designation TK-FTEB01 Series-A
Primary Part Number 51309512-175
Assembly / Secondary Number 51403483-100
Module Functional Type Fault Tolerant Ethernet (FTE) Bridge
Network Data Transfer Rate Fast Ethernet 10/100 Mbps Autonegotiating
Media Redundancy Architecture Dual-path simultaneous tracking (FTE)
System Architecture Compatibility Experion PKS and Experion LS Chassis
Physical Hardware Interface Two RJ45 Ethernet Ports
Typical Module Power Dissipation 3.5 Watts
Operating Temperature Range -40 to +70 Degrees Celsius
Diagnostics Mechanism Experion System Management Tools integration
Physical Module Dimensions 92 x 94 x 87 mm
Unit Net Weight 0.226 kg

Engineering Advantages

Distributed Control Systems (DCS) experience severe process upsets if a single network switch, port, or cable fails during operations. The TK-FTEB01 resolves this vulnerability by executing Honeywell's patented Fault Tolerant Ethernet protocol directly at the chassis interface. The module utilizes dual RJ45 ports to transmit identical control packets simultaneously across two physically isolated network paths. If a cable tears or a network switch loses power, the module switches communications to the alternative path within milliseconds without dropping data frames or tripping the controller.

The hardware features an exceptionally wide operating temperature range from -40 to +70 Degrees Celsius, which allows engineers to mount the chassis in remote, unconditioned field enclosures without risking thermal failure. A compact mechanical footprint enables straightforward slot insertion into dense Series-A backplanes, saving premium cabinet real estate. Furthermore, the firmware integrates natively with Experion System Management Tools. This native integration enables the module to transmit granular, real-time diagnostic reports regarding switch latency, port status, and signal attenuation directly to the central control room operator console.

FAQs

  • Can the TK-FTEB01 module replace old or alternative part numbers like the 51309512-125?

    Yes. The TK-FTEB01 with part number 51309512-175 serves as a direct form, fit, and functional replacement for legacy Series-A FTE bridge variants. It inserts into the same backplane slots and accepts existing Experion database configurations without requiring hardware modifications.

  • What are the primary installation requirements to ensure full network fault tolerance?

    To achieve true media redundancy, field technicians must route the two Ethernet cables from the RJ45 ports into separate industrial Ethernet switches representing Network Path A and Network Path B. Routing both cables into the same switch or running them through the same unshielded conduit defeats the fault-tolerant design.

  • Does this communication module require separate IP addresses for each RJ45 port?

    No. The Fault Tolerant Ethernet driver assigns a single, unified IP address to the TK-FTEB01 module. The underlying software automatically manages the dual-path redundancy and port status routing internally, which simplifies network architecture and saves valuable IP address allocations.

What's clients say about us