أصلي 100%. أكثر من 100,000 قطعة متوفرة. جاهزة للشحن.

  • ar

The Bently Nevada 330101-00-43-15-02-05, also cataloged as the 330101 8 mm Proximity Probe, operates as a dedicated hardware component for non-contacting vibration and position measurement within rotor dynamics monitoring systems.

Hardware Specifications

Parameter Specification
Model 330101-00-43-15-02-05
Brand Bently Nevada
Origin USA
Weight 0.2 kg
Dimensions 25.2 cm x 2.4 cm x 12.6 cm
Operating Temp -51 deg C to +177 deg C
Power Consumption Passive (Powered by Proximitor Sensor)
Probe Tip Material Polyphenylene Sulfide (PPS)
Case Material AISI 303 Stainless Steel
Linear Range 2 mm (80 mils)

Eddy-Current Probe Scaling and Rotor Dynamics

The 330101 series utilizes an eddy-current principle to detect the proximity of a conductive target. Proper scaling is required to maintain the standard 7.87 V/mm (200 mV/mil) output sensitivity provided by the matching 3300 XL Proximitor sensor. During installation, the gap voltage must be validated against a -10 VDC target at the mid-linear range to ensure linear response. Signal integrity depends on minimizing cross-talk between adjacent probes and ensuring the target material surface conforms to Bently Nevada material correction specifications to maintain accurate rotor dynamic vibration data.

Frequently Asked Questions

Q: Can the 330101 probe be utilized with older 3300 series Proximitor sensors?

A: The 330101 8 mm probe is specifically calibrated for the 3300 XL system. Compatibility with legacy 3300 (non-XL) systems requires recalibration of the Proximitor sensor to ensure the 200 mV/mil sensitivity is maintained.

Q: What are the primary installation constraints for the probe tip?

A: The probe tip must be mounted with sufficient clearance from non-target materials to prevent false readings. Ensure the probe is installed in a threaded hole with a minimum of 4 to 5 threads of engagement for structural stability in high-vibration environments.

Field Installation Guidelines

  1. Ensure the probe mounting bracket is rigid to minimize resonance effects at the probe location.
  2. Verify that the probe cable length matches the specific calibration length of the Proximitor sensor (5 m or 9 m) to avoid signal attenuation.
  3. Use high-quality coaxial connectors (click-loc) and ensure the connection is protected from environmental contaminants.
  4. Perform a bench-top gap verification using a calibrated micrometer to confirm the -10 VDC setpoint before full installation into the machinery casing.
  5. Tighten the probe locknut securely to prevent loosening under continuous machine vibration, while ensuring the tip distance remains within the linear range of the target shaft.