Configured for dynamic compensation and assignable process alarms in DCS and advanced single-loop applications, the Foxboro 761CNA-AT (761CNA Single Station Micro Plus Controller) provides direct physical/electrical execution across continuous process control networks. The controller processes standard field analog signals and executes full proportional, integral, and derivative (PID) algorithms via an integrated front panel keypad. Designed with a 32-position terminal block, nonvolatile memory backup, and modular retrofitting capability, the hardware maintains deterministic loop execution through sudden main supply interruptions.
| Parameter | Specification |
|---|---|
| Model | 761CNA-AT |
| Brand | Foxboro |
| Origin | USA |
| Weight | 3.6 kg (8.6 lbs) |
| Dimensions | 17.8 cm x 7.6 cm x 50.8 cm (7.0 in x 3.0 in x 20.0 in) |
| Operating Temp | -40 deg C to +85 deg C |
| Power Supply | 120 VAC, 50/60 Hz |
| Power Consumption | Standard internal power transformer load |
| Product Type | Single Station Micro Plus Controller |
| Input Signal | 4-20 mA DC |
| Accuracy | +/-0.25% of span typical |
| Response Time | 2 s or less |
| Control Modes | Proportional, Reset (Integral), Derivative, PID |
| Proportional Band | Adjustable 4% to 400% |
| Reset (Integral) | Adjustable 0.01 to 50 min/repeat |
| Derivative | Adjustable 0.05 to 50 min |
| Wiring Termination | 32-position terminal block |
| Enclosure Rating | NEMA 3 / IP53 |
| Mounting | Shelf-mount or retrofit into standard Foxboro shelves |
The unit integrates standard 4-20 mA DC analog current loop processing with internal cold-junction compensation pathways and isolated signal conditioning stages. Channel-to-channel isolation hardware mitigates ground-loop noise across industrial sensor installations, maintaining signal accuracy within +/-0.25% of span. The internal firmware continuously samples incoming 4-20 mA process variables (PV), updates internal setpoint calculations, and drives physical control elements without latency degrade. Nonvolatile memory registers store custom control logic and user parameters without requiring battery backup, ensuring deterministic startup and state recovery following a total 120 VAC power interruption.
Q: How does the controller retain configuration parameters during a sudden AC power loss?
A: The module relies on integrated nonvolatile memory to maintain logic control routines, tuning values, and alarm parameters. When 120 VAC main power restores, the hardware boots directly into operational state without parameter loss or recalibration requirements.
Q: What mounting configurations are supported for retrofitting older installations?
A: The chassis uses a standardized shelf-mount enclosure designed for direct insertion into existing Foxboro 760 Series panel shelves, connecting to field loops via the rear 32-position terminal block.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.