100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

Foxboro P0926KM I/A Series Termination Assembly

Configured for field transmitter interface execution in I/A Series DCS networks, the Foxboro P0926KM (P0926KM Termination Assembly) provides direct physical/electrical execution. This hardware component links field-side analog and mixed instrumentation to designated Field Bus Modules, driving raw electrical signal acquisition directly across physical connections. The passive circuitry routes low-voltage instrumentation lines to ensure zero-latency transmission to the subsystem digitization hardware without altering structural wave characteristics.

Hardware Specifications

Parameter Specification
Model P0926KM
Brand Foxboro (Schneider Electric)
Origin United States
Weight 0.30 lbs
Dimensions Standard FBM Type 4-inch base footprint
Operating Temp -20 to +60 deg C
Power Consumption Passive (Powered via FBM backplane)
Channel Capacity Multi-channel variable based on paired FBM
Signal Types 4-20 mA current loops, voltage signals, thermocouples, RTDs
Termination Type Screw-clamp terminals (12-22 AWG) with 3-pin interface
Isolation Channel-to-channel and channel-to-ground isolation
Mounting DIN rail or rack base
Storage Temperature -40 to +85 deg C
Enclosure Rating IP20 (Cabinet installation required)
Diagnostics Open-circuit and short-circuit detection via FBM
Certifications CE, UL, cUL, ATEX

Process Control & DCS Instrument Characteristics

The P0926KM architecture implements physical path layouts engineered for 4-20 mA HART loop protocol integrity. Structural traces minimize capacitive loading across adjacent paths, maintaining signaling thresholds for FBM measurement subsystems. Structural channel-to-channel isolation prevents ground loop currents from injecting electrical noise into parallel loops. For temperature measurement loops, the terminal configuration provides thermal equilibrium across physical termination boundaries, maintaining reference stability for cold junction compensation (CJC) processing performed by the paired active FBM.

Frequently Asked Questions

Q: Does the P0926KM require manual configuration or firmware validation?

A: No. The assembly operates purely as a physical termination module. It contains no active microprocessors or flash memory, making firmware cross-compatibility non-applicable.

Q: What are the electrical constraints regarding hot-swapping field wiring on this unit?

A: Hot-swapping the modular wiring interface is supported; however, loop power must be external or derived directly through the FBM backplane to prevent inductive spikes from damaging terminal contacts during physical disconnection.

Q: Can the 3-pin configuration be adapted for high-density differential voltage inputs?

A: The physical channel configuration matches the specific pin-out of the paired FBM. Modifying the physical 3-pin pathing outside factory specifications will break signal continuity and invalidate ATEX certifications.

Field Installation Guidelines

  • Terminal Torque Specifications: Field wiring connections using the screw-clamp terminals must accept 12 to 22 AWG conductors. All screws must be torqued precisely to standard industrial guidelines to maintain physical contact without fracturing the internal trace bonds.
  • Shield Grounding Disconnect: Field transmitter cable shields must terminate strictly at a single point on the central cabinet instrument ground bar. Do not ground shields at both the P0926KM terminals and the field device to prevent circulating ground loop interference.
  • Separation of Control Signals: Route all 4-20 mA, RTD, and thermocouple field cabling through dedicated low-voltage wire trays. Maintain a minimum separation of 300 mm from high-voltage AC power distribution line runs to prevent inductive noise coupling.
  • Enclosure Requirements: The module is rated IP20. Physical mounting must be executed within an environment-controlled, dust-protected NEMA Type 4 or IP54 equivalent industrial enclosure to meet full environmental temperature ratings.

¿Qué dicen nuestros clientes sobre nosotros?