Configured for high-density single-ended analog data capture in distributed Genius Bus networks, the GE Fanuc IC670ALG230 (IC670ALG230 Analog Current Input Module) provides direct physical/electrical execution. This hardware component converts 0-20 mA or 4-20 mA loop currents into 12-bit digital data across eight single-ended channels. The module executes signal digitized conversion within 60 microseconds per channel and forwards these data bits directly to the head-end Bus Interface Unit (BIU). A 1500 VAC electrical barrier isolates the field-side loops from the internal processing architecture to block transient surges.
| Parameter | Specification |
|---|---|
| Model | IC670ALG230 |
| Brand | GE Fanuc |
| Origin | USA |
| Weight | 0.26 kg |
| Dimensions | Standard Field Control footprint |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 51 mA maximum from BIU backplane |
| Number of Channels | 8 (Single-ended) |
| Input Signal Range | 0.0 mA to 25.0 mA |
| Digital Resolution | 12-bit (5.0 uA per LSB) |
| Conversion Time | 60 microseconds per channel |
| Input Impedance | 250 ohms |
| External Power Supply | 24 VDC (18-30 VDC range) |
| Isolation | 1500 VAC (1 minute), 250 VAC (Continuous) |
| Non-linearity | plus or minus 0.025% of full scale |
| Accuracy | plus or minus 0.05% of full scale at 25 deg C |
The module implements software-selectable 50 Hz or 60 Hz digital notch filters to reject ambient industrial electrical noise from corrupting data registers. Backplane bus communication velocity handles the continuous stream of 12-bit processed values, matching the module-level conversion latency. Users scale I/O density by slot configuration on the local Field Control basebook. Firmware flash compatibility rules require that the head-end Bus Interface Unit recognizes the device hardware ID to maintain appropriate network synchronization across the deterministic distributed Genius Bus topology.
Q: How does the module react if an external 24 VDC loop power supply drops below 18 VDC?
A: The hardware detects the undervoltage fault, ceases valid conversion cycles, and drives corresponding diagnostic failure bits to the BIU over the backplane bus.
Q: Can the internal analog-to-digital matrix withstand continuous high-voltage spikes?
A: The module maintains continuous galvanic isolation up to 250 VAC. Transient exposures up to 1500 VAC are withstood for a maximum duration of 1 minute without destruction of internal components.
Q: Does the 250 ohm input impedance require an external precision shunt resistor?
A: No, the 250 ohm precision termination resistors are completely integrated into the physical circuit layout of each individual input channel.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.