100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

The GE Fanuc IC200CBL001, also cataloged as the IC200CBL001 Programming Cable, operates as a dedicated hardware component for point-to-point serial data transfer within VersaMax system networks. The cable provides an RS-232 connection between programming workstations and RS-232 Port 1 on the PLC controller.

Hardware Specifications

Parameter Specification
Model IC200CBL001
Brand GE Fanuc
Origin USA
Weight 0.31 lbs (0.14 kg)
Dimensions 15 m (50 ft) cable length
Operating Temp Up to 80 deg C maximum
Power Consumption Passive physical media (30 V voltage rating)
Cable Type Straight-through RS-232 serial cable
Connectors 9-pin D-sub male to 9-pin D-sub female (crimp style)
Data Transfer Rate Up to 115,200 bps maximum
Conductor Specification 24 AWG copper
Shielding Overall electromagnetic interference (EMI) shield
Designated Port RS-232 Port 1 on VersaMax PLC

Backplane Bus Communication Velocity & Firmware Flash Compatibility

The serial cable facilitates hardware link execution at data transmission rates up to 115,200 bps without introducing physical latency over its 15 m length. The assembly utilizes 24 AWG copper conductors enveloped in a grounded shield layer to suppress signal cross-talk and ambient high-frequency noise. This physical media path ensures firmware flash compatibility and error-free bit-stream delivery during PLC CPU memory clearing, program downloading, and online logic execution monitoring via serial Port 1.

Frequently Asked Questions

Q: What connector types are constructed on the ends of the IC200CBL001 cable?

A: The cable utilizes a 9-pin D-sub male connector on one end and a 9-pin D-sub female connector on the opposite end.

Q: What is the maximum baud rate supported by the cable assembly?

A: The cable supports serial communication data rates up to a maximum of 115,200 bps.

Q: Does the IC200CBL001 cable incorporate noise shielding?

A: Yes, the cable incorporates an integrated shielding layer over 24 AWG copper conductors to prevent electromagnetic interference.

Field Installation Guidelines

  1. Inspect both 9-pin D-sub connectors for bent pins or debris prior to attachment.
  2. Connect the cable directly to RS-232 Port 1 on the VersaMax PLC unit.
  3. Attach the opposite 9-pin connector to the serial port of the programming computer or serial converter.
  4. Tighten connector jack-screws finger-tight to secure electrical contact and maintain ground continuity through the shield.
  5. Route the 15 m cable away from high-voltage AC power lines and variable frequency drive output cables.