The GE Fanuc IC200UDR005, also cataloged as the IC200UDR005 PLC Module, operates as a dedicated hardware component for direct discrete signal processing and serial communications within VersaMax system networks. The unit integrates 16 24VDC inputs, 11 relay outputs, and 1 24VDC output on board, managing up to 28 local I/O points.
| Parameter | Specification |
|---|---|
| Model | IC200UDR005 |
| Brand | GE Fanuc |
| Origin | USA |
| Weight | 2.00 lbs (0.91 kg) |
| Dimensions | Compact VersaMax Micro Controller Footprint |
| Operating Temp | 0 deg C to 60 deg C |
| Power Consumption | 24 VDC (Internal Logic/Field Power) |
| Onboard I/O Count | 28 points (16x 24VDC Inputs, 11x Relay Outputs, 1x 24VDC Output) |
| Discrete Expansion Units | 4 units maximum |
| Analog Expansion Units | 4 units maximum |
| Maximum Physical I/O | 140 points total |
| User Program Memory | 9K Words logic memory |
| Register Memory | 2K Words |
| Communication Ports | Port 1: RJ-45 (RS-232); Port 2: DB-15 (RS-485) |
| Adjustment Interface | 2 Onboard Analog Potentiometers |
The controller expands system capability by interfacing up to 4 discrete expansion units and 4 analog expansion units across the backplane bus, scaling physical density up to 140 total I/O points. System logic executes within 9K words of user program memory alongside 2K words of register space. Serial interfaces (RJ-45 RS-232 and DB-15 RS-485) handle communications and program downlines, while firmware flash compatibility ensures synchronized parameter updates across connected expansion frames.
Q: What is the maximum expansion capability of the IC200UDR005 system?
A: The module supports up to 4 discrete I/O expansion units and 4 analog I/O expansion units, bringing the total system physical I/O capacity to 140 points.
Q: How are communication interfaces assigned on the controller body?
A: Port 1 is an RJ-45 connection configured for RS-232 serial communication, while Port 2 utilizes a DB-15 connector supporting RS-485 serial communication.
Q: What onboard adjustments are provided directly on the hardware unit?
A: The module incorporates 2 integrated analog potentiometers to make manual data and timer/counter value adjustments without software intervention.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.