Configured for translating universal backplane levels to serial signal levels in expansion architectures, the GE Fanuc IC695LRE001 (IC695LRE001 Serial Bus Transmitter) provides direct physical/electrical execution.
| Parameter | Specification |
|---|---|
| Model | IC695LRE001 |
| Brand | GE Fanuc Emerson |
| Origin | United States |
| Weight | 0.31 lbs (0.14 kg) |
| Dimensions | Single-Slot RX3i Form Factor |
| Operating Temp | 0 - 60 deg C |
| Power Consumption | 132 mA at 5 VDC / 0 mA at 3.3 VDC |
| Module Type | Serial Bus Transmitter |
| Effective Data Rate | 500 kbps |
| Isolation Type | Non-isolated differential communications |
| Local Cable Limit | 50 ft |
| Remote Cable Limit | 700 ft |
| Diagnostic Interface | 2 LED Indicators (Expansion OK, Expansion Active) |
The transmitter drives high-speed differential signals to bridge data from the RX3i universal chassis to remote or expansion racks. Because it lacks galvanic isolation, the physical layer utilizes tightly managed non-isolated differential signaling to maintain deterministic backplane bus communication velocity across extended line lengths. Signal propagation latencies remain constant to ensure that remote I/O processing times correspond directly with the main CPU execution cycle.
Q: What are the consequences of removing the IC695LRE001 transmitter while the backplane is energized?
A: This module does not support hot-swap capabilities. Removing the unit under power will disrupt the differential bus continuity, causing an immediate remote drop loss error and forcing all downstream I/O modules into their pre-configured fail-safe or hold-last-state conditions.
Q: Why does the "Expansion Active" LED remain completely dark despite the "Expansion OK" LED being illuminated?
A: The "Expansion OK" LED indicates that the local 5 VDC rail is within proper threshold bounds. A dark "Expansion Active" LED indicates that while the module is powered, there is no active serial packet transmission or polling occurring between the local universal backplane and the remote expansion racks.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.