The GE IS200ECTBG1ABB, also cataloged as the IS200ECTB Excitation Contact Terminal Board, operates as a dedicated hardware component for contact input monitoring and output relay interface execution within Mark VI EX2100 excitation control system platforms. Operating in redundant system configurations, the board powers 52G generator breaker online status inputs and 86G lockout inputs at 70 VDC while interfacing four general-purpose Form-C relay outputs under EMIO controller management.
| Parameter | Specification |
|---|---|
| Model | IS200ECTBG1ABB |
| Brand | GE (General Electric) |
| Origin | USA |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 70 VDC contact wetting supply / system power |
| Series | Mark VI IS200 |
| Product Type | Excitation Contact Terminal Boards |
| Functional Acronym | ECTB |
| System Configuration | Redundant mode |
| Interfacing Modules | EMIO (Control), EPCT, EXTB, EACF (I/O) |
| Dedicated Inputs | 52G (Generator online status), 86G (Lockout input) |
| Wetting Voltage | 70 VDC powered inputs |
| Output Contacts | 4 Form-C relays (e.g., 94EX, 30EX auxiliary outputs) |
| Documentation Reference | GEI-100457 / GEH-6632 |
The IS200ECTBG1ABB routes field signals through high-density discrete terminal paths managed directly by the EMIO controller board. By processing contact inputs and Form-C output coil states in synchronization with EPCT, EXTB, and EACF terminal boards, the module bypasses standard backplane bus communication velocity constraints. Digital logic hardware validates real-time contact states and relay auxiliary feedback while firmware flash compatibility across the Mark VI platform ensures synchronized trip and status signal execution in redundant excitation architectures.
Q: Which primary control module manages signal processing for the IS200ECTBG1ABB terminal board?
A: The board is managed by the EMIO control board alongside associated EPCT, EXTB, and EACF terminal modules.
Q: What power source is applied to the 52G and 86G discrete contact inputs on the ECTB board?
A: The board internally supplies 70 VDC wetting power to monitor the 52G generator breaker status and 86G lockout inputs.
Q: What relay outputs are driven by the four Form-C contacts on this board?
A: The Form-C dry/wet contacts drive trip and auxiliary output circuits such as 94EX and 30EX, monitoring relay coil currents and auxiliary contact states.