The GE Fanuc IC200ALG230, also cataloged as the IC200ALG230 Analog Input Module, operates as a dedicated hardware component for multi-range process variable digitization within VersaMax PLC and Network Interface Unit architectures. The module converts field transmitter signals across 4 single-ended channels into 12-bit digital values, routing real-time data directly to the local CPU or distributed I/O station backplane.
| Parameter | Specification |
|---|---|
| Model | IC200ALG230 |
| Brand | GE Fanuc / Emerson |
| Origin | USA |
| Weight | 0.14 kg |
| Dimensions | 110 mm x 66.8 mm x 50 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 125 mA at 5 VDC backplane supply (+24 VDC external for current loop) |
| Input Channels | 4 single-ended channels |
| Resolution | 12-bit (1 part in 4096) |
| Signal Ranges | 0 to +10 VDC, -10 to +10 VDC, 4 to 20 mA |
| Input Impedance | >1 Mohm (Voltage), 250 ohm (Current) |
| System Accuracy | +/-0.25% of full scale at 25 deg C |
| Response Time | 5.0 ms (0.4 ms update rate) |
| Isolation | 250 VAC continuous; 1500 VAC for 1 min (field group to backplane) |
The IC200ALG230 leverages the high-speed VersaMax backplane bus communication velocity to execute frame updates within 0.4 ms across all 4 input channels. Embedded firmware flash compatibility maintains automatic configuration mapping between the module and VersaMax CPUs or Ethernet Network Interface Units (NIU). The board incorporates 125 mA backplane current management and group-to-backplane isolation rated at 1500 VAC to maintain deterministic data delivery without signal cross-talk or backplane bus dropouts.
Q: How is the IC200ALG230 switched from voltage sensing to 4-20 mA current mode?
A: Current inputs require placing physical hardware jumpers across the designated input channel terminals on the carrier board alongside matching software range selections.
Q: Can the IC200ALG230 be inserted or removed while backplane power is active?
A: Hot-swapping is supported only when the module is mounted on a compatible VersaMax I/O carrier, provided field-side sensor power is isolated prior to module extraction.
Q: What diagnostic flags does the module report back to the VersaMax CPU?
A: The onboard logic monitors power status and reports internal power loss events along with software configuration out-of-range errors to the main controller fault table.
Snap the IC200ALG230 module into its designated VersaMax I/O carrier until the latch mechanism engages firmly with the backplane connector. Ensure field power is de-energized before wiring signals. Connect shielded twisted-pair cables to the carrier terminals, maintaining separate wire routing from high-voltage AC cables inside the enclosure. Ground all cable shields to the cabinet ground bar at a single point to mitigate ground loops. Verify external 24 VDC power supply polarity when powering 4-20 mA current loops to ensure accurate ADC conversions.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.