Configured for Ethernet Global Data (EGD) exchange and remote I/O control in Series 90-30 platforms, the GE Fanuc IC693NIU004 (IC693NIU004 Ethernet Network Interface Unit) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model IC693NIU004
Brand GE Fanuc Emerson
Origin USA
Weight 1.81 lbs (0.82 kg)
Dimensions Single-slot Series 90-30 module width
Operating Temp 0 to 60 deg C
Power Consumption Standard Series 90-30 backplane power draw
Memory Storage RAM and Flash
Network Interfaces Two (2) RJ45 Ethernet ports (10/100 Mbps, auto-sensing/auto-negotiation)
IP Configuration Single (1) IP address with integrated dual-port Ethernet switch
Discrete Input Capacity (%I) 2048 points
Discrete Output Capacity (%Q) 2048 points
Analog Input Capacity (%AI) 1268 words
Analog Output Capacity (%AQ) 512 words
Memory Registers 4096 internal coils (%M), 256 temporary coils (%T), 9999 register memory
Protocol Support EGD (Ethernet Global Data), SRTP Server, SNP/SNPX (via power supply RS-485 port)
Supported Baseplates Up to 8 baseplates (1 CPU baseplate + 7 expansion/remote baseplates)
Diagnostics & Control EOK, LAN, STAT, and PS PORT LEDs; integrated Ethernet restart pushbutton

Backplane Bus Communication Velocity & Network Integration

The IC693NIU004 interface module routes field data between local baseplates and host control networks, maintaining high backplane bus communication velocity and deterministic synchronization. Its internal switch architecture processes up to 2048 discrete inputs, 2048 discrete outputs, 1268 analog input words, and 512 analog output words without requiring external Ethernet switches. Dedicated memory registers (4096 %M coils, 256 %T coils, and 9999 holding registers) maintain operational data integrity across Flash and RAM memory blocks. Firmware flash compatibility across the Series 90-30 backplane allows unified logic control via SRTP server and EGD protocols using CIMPLICITY Machine Edition configuration utilities.

Frequently Asked Questions

Q: How does the dual-port Ethernet switch operate on the IC693NIU004?

A: The two 10/100 Mbps auto-sensing RJ45 Ethernet ports share a single IP address, functioning as an integrated network switch to support Linear, Star, and Ring physical network topologies without additional hardware.

Q: What is the function of the front-panel Ethernet restart pushbutton?

A: The restart pushbutton re-initializes the internal network interface hardware and communication stack without disrupting main backplane logic power or requiring configuration software connections.

Q: What maximum I/O memory register capacities are processed by this interface unit?

A: The module handles up to 2048 discrete inputs (%I), 2048 discrete outputs (%Q), 1268 analog input words (%AI), and 512 analog output words (%AQ) across connected expansion racks.

Field Installation Guidelines

  1. Remove main system power from the Series 90-30 baseplate prior to inserting or removing the network interface unit.
  2. Align the IC693NIU004 with the selected single-slot slot location on the baseplate, pressing firmly until the backplane bus connector fully seats.
  3. Fasten the module panel retention screw to secure chassis earth grounding and protect against industrial vibration.
  4. Connect Category 5e/6 industrial Ethernet cables to the dual RJ45 ports, ensuring minimum bend radius rules and strain relief practices are observed.
  5. Maintain dedicated wireways for Ethernet network cabling separated from high-voltage AC lines to prevent electro-magnetic interference.