The ABB INCIT01 functions as the high-performance communication backbone for the INFI 90® and Symphony Harmony distributed control systems (DCS). This Communication Interface Module establishes a secure and deterministic link between local process controllers, operator workstations, and external supervisory networks. By managing complex data traffic and protocol conversion, the INCIT01 ensures that real-time process data reaches the HMI without latency. It serves as a vital gateway for facilities requiring seamless integration between legacy control layers and modern Ethernet-based plant management systems.
The INCIT01 utilizes a ruggedized circuit architecture to maintain 24/7 network stability in demanding industrial environments.
| Attribute | Technical Data |
| Manufacturer | ABB (Bailey Controls) |
| Model Number | INCIT01 |
| Module Type | Communication Interface Module |
| System Compatibility | INFI 90® / Symphony Harmony DCS |
| Protocols Supported | Ethernet TCP/IP, Modbus, Infi-Net |
| Operating Voltage | 24 V DC |
| Power Consumption | 10 W |
| Isolation | Galvanic isolation (Communication to Control Logic) |
| Operating Temperature | -20°C to +70°C |
| Dimensions | 10 × 4.5 × 12 cm |
| Protection | EMI Shielding and Surge Protection |
Multi-Protocol Interoperability: The INCIT01 natively supports Ethernet TCP/IP, Modbus, and Infi-Net. This versatility allows engineers to bridge the INFI 90 controllers with diverse third-party hardware and modern SCADA software, eliminating the need for expensive external protocol converters.
Galvanic Signal Integrity: High-speed communication lines often introduce electrical noise into the control rack. The INCIT01 incorporates full galvanic isolation, creating an effective barrier that prevents external transients from corrupting internal processor logic or I/O data.
Optimized for Harsh EMI Environments: Designed for placement near high-voltage switchgear and heavy motor loads, the INCIT01 features multi-layer EMI shielding. This ensures data packets remain intact even in environments with significant electromagnetic interference.
Deterministic Data Buffering: The module manages internal data queues to prioritize critical control traffic. During high-bandwidth events, such as plant-wide alarms, the INCIT01 ensures that vital controller-to-operator station updates maintain precedence over standard diagnostic traffic.
Maintenance-Friendly Hot-Swapping: The modular design allows for live replacement. Technicians swap modules while the rack remains powered, ensuring that communication maintenance on one segment does not force a shutdown of the active process control loops.
100% Brand New Condition: We deliver only original, factory-sealed ABB INCIT01 units. This guarantees the highest MTBF (Mean Time Between Failures) and ensures the internal capacitors and communication chips meet modern reliability standards for critical infrastructure.
Q: Does the INCIT01 require specific software for protocol configuration?
A: Configuration typically occurs within the ABB Composer or WinTools environment. You define the Modbus registers or Ethernet parameters within the standard DCS engineering suite to activate the communication paths.
Q: Can the INCIT01 facilitate communication with Symphony Plus systems?
A: Yes. Since Symphony Plus often utilizes the Harmony rack architecture for I/O and communication, the INCIT01 remains a standard interface for linking legacy INFI 90 segments with modernized Symphony Plus controllers.
Q: How does the module handle a network failure?
A: The INCIT01 supports redundant network topologies. In a dual-network configuration, the module automatically detects a loss of signal on the primary line and switches to the secondary path to maintain uninterrupted data flow to the operator station.
Q: Is external power required for the Ethernet port?
A: No. The INCIT01 draws all necessary operating power from the DCS rack backplane. The communication signals are self-powered through the interface circuitry, though external networking hardware (like switches) requires its own power source.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.