100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

The Schneider TSXDEY32D2K is a high-density discrete input module designed for the Modicon Premium PLC platform. It provides 32 isolated current sink inputs, specifically engineered to interface with 2- or 3-wire proximity sensors in demanding industrial automation environments. This module offers reliable signal processing with robust electrical isolation and fast response times.

Features

  • 32 isolated discrete input channels.
  • Compatible with standard 24 V DC positive logic.
  • Designed for integration with 2- or 3-wire proximity sensors.
  • High input impedance for signal integrity.
  • Standard HE-10 connector interface for efficient wiring.
  • Low power dissipation design suitable for high-density rack configurations.

Applications

This module is typically utilized in manufacturing and process control systems where high-density digital signal acquisition is required, such as conveyor control, assembly line monitoring, and machine safety interlocks within the Modicon Premium ecosystem.

Technical Specifications

Model Number TSXDEY32D2K
Platform Modicon Premium PLC
Number of Inputs 32 isolated current sink
Input Voltage 24 V DC positive
Sensor Power Supply 19 to 30 V DC
Input Current 3.5 mA
Input Impedance 6300 Ohm at state 1
Voltage Threshold (State 1) >= 11 V
Voltage Threshold (State 0) <= 5 V
Response Time <= 7 ms
Electrical Isolation > 10 MOhm at 500 V DC
Power Dissipation 1 W + 0.1 W per active channel
Current Consumption 135 mA at 5 V DC / 160 mA at 24 V DC
Connection Type HE-10 connector
Operating Temperature 0 degC to +60 degC

Installation Guidelines

  • Ensure the PLC rack is powered down before inserting or removing the module to prevent electrical damage.
  • Use shielded cables for input signals to minimize electromagnetic interference (EMI) in high-noise industrial environments.
  • Verify that the sensor power supply is within the 19–30 V DC range before connecting field devices.
  • Ensure proper grounding of the Modicon Premium rack to maintain electrical isolation integrity.
  • Handle the module by the housing to avoid electrostatic discharge (ESD) damage to the internal circuitry.

FAQ

What type of sensors can be used with the TSXDEY32D2K?

This module is designed for use with 2- or 3-wire proximity sensors operating on 24 V DC positive logic.

What is the connection interface for this module?

The module utilizes a standard HE-10 connector for field wiring, which facilitates quick and reliable connections to terminal blocks or distribution boards.

What's clients say about us