The Schneider Electric 171CCC96020, also cataloged as the 171CCC96020 M1/M1E Processor Adapter Module, operates as a dedicated hardware component for high-speed logic execution and industrial network routing within Modicon Momentum automation system platforms. This hardware unit mounts directly onto a compatible Momentum input/output base assembly to control localized electronic channels. By serving as the primary processing node, the module reads connected data registers, runs cyclic application routines, and exchanges parameters across distributed field networks via its integrated communication interfaces.

Hardware Specifications

Parameter Specification
Model 171CCC96020
Brand Schneider Electric (Modicon)
Origin France
Weight 0.20 kg (0.45 lbs) net module / 0.45 kg (1.00 lbs) shipping package weight
Dimensions Standard Modicon Momentum processor block envelope
Operating Temp 0 to 60 deg C
Power Consumption Supplied directly via internal Momentum I/O base backplane interface
Processor Architecture M1E Controller core running a 16-bit word length layout
Clock Frequency 50 MHz
Flash Memory Capacity 512 kB for non-volatile executive and application storage
Internal RAM Capacity 544 kB (512 kB allocated for runtime variable storage arrays)
Logic Execution Scan Time 0.3 milliseconds per kilobyte (1K) of compiled program instructions
Discrete I/O Capacity 8192 bits maximum input and output point limits
Register I/O Capacity 26048 words maximum processing limit
Communication Interfaces 1 x Ethernet TCP/IP port, 1 x local Input/Output bus port
Storage Temperature -40 to 85 deg C
Operating Humidity 5 to 95 percent relative humidity non-condensing
IP Degree of Protection IP20
Certifications CE, UL, CSA, FM Class 1 Division 2, IEC 61131-2

Note on communication protocols: While basic Momentum adapters utilize token-passing Modbus Plus topologies, the specific 171CCC96020 M1E hardware variant integrates an onboard open Ethernet TCP/IP network interface to execute deterministic processing loops.

Profinet and EtherNet/IP Deterministic Networks

This processor adapter expands the capability of modular field racks by routing control variables natively over modern industrial network fabrics. The internal embedded web server and communication stack support high-density I/O density scaling by executing standard Modbus TCP/IP master/slave client routines directly over its 50 MHz execution block. Firmware flash compatibility tools enable engineers to update the onboard 512 kB storage sectors via the network line, ensuring that connection handling parameters match current software revisions without requiring physical extraction of the processor card. This connectivity allows the module to feed real-time register words to supervisory host architectures while maintaining a fast 0.3 ms per kilobyte processing velocity across local discrete I/O channels.

Frequently Asked Questions

Q: How is the volatile application data inside the 171CCC96020 RAM section preserved during a complete power loss?

A: The 171CCC96020 processor module relies on an internal storage capacitor circuit combined with non-volatile memory sectors to maintain structural code retention. For long-term preservation of active data registers when the I/O base loses primary input power, a secondary internal hardware battery circuit maintains the integrity of the 544 kB RAM table.

Q: Can this processor module be hot-swapped or separated from the underlying I/O base while the system is energized?

A: No. The internal parallel logic bus interface pins linking the 171CCC96020 adapter to the Momentum I/O base do not feature specialized arc suppression or electrical isolation mechanisms. Unmating the processor adapter while power is applied can damage the internal microprocessor or cause the main backplane bus to crash.

Q: What action must be taken if a memory expansion fault code is flagged during standard application download routines?

A: A memory configuration error indicates that the compiled application size exceeds the physical boundaries of the 512 kB flash or data allocations inside the 544 kB RAM. Program optimization must be executed to reduce register allocation counts, or the system hardware configuration must transition toward higher-tier ePAC structures like the Modicon M580 series.

Field Installation Guidelines

  • Base Mechanical Interlocking: Align the plastic guide clips of the processor adapter carefully with the structural receiver slots on top of the de-energized Momentum I/O base, pressing downward firmly until both side latches engage completely.
  • Ethernet Shield Isolation: Terminate the outer metal shield of the RJ45 industrial Ethernet cable directly to the enclosure master grounding plate, avoiding paths that could inject transient voltages into the communication port.
  • Bus Termination Verification: Ensure that any specialized serial I/O bus cable connected to the auxiliary network port incorporates matching characteristic resistors at the furthest physical endpoints to eliminate wave reflections.
  • Thermal Convection Positioning: Mount the combined base and adapter block horizontally inside the control panel, leaving a minimum vertical spacing clearance of 50 mm above and below the assembly to prevent heat saturation.