أصلي 100%. أكثر من 100,000 قطعة متوفرة. جاهزة للشحن.

  • ar

YOKOGAWA F3BU13-0N Base Module Assembly

The YOKOGAWA F3BU13-0N, also cataloged as the F3BU130N Base Module Assembly, operates as a dedicated hardware component for module housing and signal bus distribution within FA-M3 PLC system platforms.

Suffix Breakdown & Model Matrix

  • F3BU13: Base model identifier for 13-slot capacity backplane units within the FA-M3 series.
  • -0N: Configuration suffix denoting standard backplane revision and mechanical assembly standards for rack-mounted PLC logic components.

Hardware Specifications

Parameter Specification
Model F3BU13-0N
Brand YOKOGAWA
Origin Japan
Weight 1.5 kg
Dimensions 450 × 100 × 126 mm
Operating Temp 0 deg C to +55 deg C
Power Consumption Passive bus distribution
Total Slots 13
Bus Type FA-M3 Proprietary High-Speed

PLC Control & Deterministic Network Attributes

The F3BU13-0N serves as the physical foundation for the FA-M3 backplane, providing a deterministic communication path for data exchange between the CPU, I/O modules, and communication interfaces. The assembly features a high-density, multi-layer printed circuit backplane designed for low-impedance signal routing and crosstalk suppression. To ensure consistent system performance, the backplane bus supports synchronized backplane bus communication velocity management, which prevents signal reflection and packet corruption during high-frequency data transactions across all 13 slots. The integrated power distribution rails are engineered to maintain stable voltage levels for all mounted modules, minimizing thermal stress on the component logic.

Frequently Asked Questions

Q: Does the F3BU13-0N include an integrated power supply?

A: No. The base unit acts as a passive backplane for module interconnection. The power supply (e.g., F3PU30-0S) must be installed in the designated leftmost slot of the rack to provide power to the backplane.

Q: Can modules be inserted or removed while the rack is powered?

A: No. The F3BU13-0N does not support hot-swapping. All power must be removed from the base unit prior to the insertion or removal of any PLC module to prevent electrical damage to the backplane connector pins.

Q: Is the backplane bus compatible with all FA-M3 modules?

A: The backplane is compatible with the standard FA-M3 module series. Always verify module-to-slot compatibility in the system configuration software to ensure correct addressing and bus bandwidth allocation.

Field Installation Guidelines

  • Mounting: Install the base unit on a flat, vibration-dampened panel or a rigid DIN-rail system. Ensure the unit is leveled to prevent mechanical stress on the backplane connectors.
  • Grounding: Connect the frame ground (FG) terminal of the base unit to a low-impedance cabinet earth point using a multi-strand copper conductor. This is required for electromagnetic compatibility and noise suppression.
  • Slot Allocation: Occupy the leftmost slot with the power supply module. Distribute heavy I/O modules evenly across the remaining 12 slots to promote balanced thermal dissipation.
  • Connectivity: Ensure all modules are fully seated and the retaining screws are tightened to establish consistent electrical contact with the backplane bus. Avoid over-tightening, which may deform the housing.