Configured for high-precision mass flow and density measurement in process automation environments, the Yokogawa RCCF31-AH2M/KF2/BG/X1/IE1 (RCCF31 Remote Field Mount Converter) provides direct physical/electrical execution. This field-mountable signal processing unit interfaces with ROTAMASS Coriolis flow sensor detectors, processing primary raw sensor signals into digitized mass flow, volume flow, fluid density, and process temperature data outputs. Operating on 90-250 V AC power at 47/63 Hz with a power consumption limit of 10 W, the assembly delivers dual analog outputs alongside HART signal modulation across process automation loops.
| Parameter | Specification |
|---|---|
| Model | RCCF31-AH2M/KF2/BG/X1/IE1 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 3.9 kg (8.6 lbs) |
| Dimensions | Standard ROTAMASS field converter housing |
| Operating Temp | -20 deg C to +60 deg C |
| Power Consumption | 10 W maximum |
| Supply Voltage | 90 to 250 V AC (47/63 Hz) or 24 V DC option |
| Enclosure Rating | IP66 / IP67, flameproof explosion-proof housing |
| Mass Flow Accuracy | +/-0.1% of reading (+/-0.05% optional) |
| Density Accuracy | +/-0.0005 g/cm3 |
| Temperature Range | -200 deg C to +350 deg C (process fluid via connected sensor) |
| Process Pressure Limits | Up to 100 bar (sensor dependent) |
| Digital Communication | 4-20 mA HART, FOUNDATION Fieldbus, Modbus, PROFIBUS |
| Physical Interface | ANSI 1/2 in NPT female thread conduit connection |
The RCCF31-AH2M/KF2/BG/X1/IE1 incorporates a dedicated 4-20 mA HART loop protocol physical layer alongside support for FOUNDATION Fieldbus and PROFIBUS digital field network communication. The converter overlays digital Frequency-Shift Keying (FSK) diagnostic data onto primary 4-20 mA analog output channels, facilitating real-time telemetry transfer for process mass flow, secondary density metrics, and sensor diagnostic flags without interrupting primary current loop signals. Passive status outputs rated to 30 V DC, 200 mA provide direct pulse or discrete alarms to host DCS interface cards. Integrated cold junction compensation (CJC) algorithms process RTD resistance readings from the remote sensor tube to ensure temperature-corrected density calculations across thermal swings.
Q: What conduit connections are provided on the field enclosure?
A: The converter enclosure features ANSI 1/2 in NPT female threaded cable entries designed for explosion-proof conduit engagement or certified Ex d cable glands.
Q: How does the unit isolate passive pulse and analog outputs from external loop noise?
A: Internal galvanic isolation barriers separate field output terminals from the main power supply and digital signal processing circuitry, mitigating ground loop interference and maintaining output stability under high electrical noise conditions.
Q: Is the high-visibility LCD operable in low-ambient temperature field installations?
A: The integrated multilingual LCD module maintains clear visual refresh rates across operating ambient temperatures down to -20 deg C without degradation of process variable readability.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.