The YOKOGAWA ST3*A serves as the primary ST3 A System Bus Interface Module utilized to execute deterministic data transfer across CENTUM VP platforms. This hardware component mounts directly into the field control unit (FCU) rack slot to establish a physical and electrical communication link between the internal logic processors and the external ESB/ER extension buses. The unit processes field signal configurations via embedded diagnostic circuitry, utilizing localized light-emitting diodes (LEDs) to monitor link status, bus activity, and hardware faults in real time.
| Parameter | Specification |
|---|---|
| Model | ST3*A (ST3 A) |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 0.4kg |
| Dimensions | 120 x 25 x 130 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 5 VDC, ~1.2 A |
| System Compatibility | CENTUM VP, CS 3000 |
| Communication Protocol | ESB/ER bus |
| Redundancy | Dual-redundant communication supported |
| Data Transfer Rate | 100 Mbps (typical) |
| Isolation | 1500 VAC (system-to-bus, 1 min) |
| Signal Density | 32 points (16 x 2 configuration) |
| Field Connection Type | M4 Screw Terminals |
| Diagnostics | LED indicators for link, activity, and fault |
| Humidity Range | 5 to 95% RH, non-condensing |
| Mounting | Rack-mounted (FCU slot) |
| Certifications | CE, UL, RoHS compliant |
The YOKOGAWA ST3*A incorporates channel-to-channel isolation architecture to prevent high-voltage transients from compromising the internal system bus logic during active data acquisition. Operating over the ESB/ER bus protocol, the module provides a strict 1500 VAC galvanic isolation barrier between the processing logic and external physical lines. Internal circuitry mitigates common-mode noise issues, allowing the 32-point signal distribution matrix to maintain linear signal integrity without zero-drift distortion. The module dynamically manages data packet prioritization over the 100 Mbps communication medium, enabling continuous synchronization between remote expansion chassis and the master controller.
Q: How does the module handle a communication failure on the primary ESB/ER bus line?
A: The module executes a dual-redundant tracking routing strategy. If the primary extension bus link experiences a packet timeout or signal degradation, the onboard hardware logic initiates a hot-standby switchover to the secondary redundant bus line without causing an interruption in the control process.
Q: Is it permissible to perform an online hot-swap of this module while the FCU is live?
A: Yes, online replacement is supported provided that the parallel tracking module is fully functional and synchronized. The field technician must confirm that the active mate displays a solid green link status and no fault indications before extracting the module from the backplane connector.
Q: What are the primary structural differences between the two weight specifications listed in product variants?
A: The base rack-mounted card component weighs approximately 0.35 kg, whereas variations equipped with integrated M4 screw terminal block assemblies and structural field wiring enclosures weigh up to 1.5 kg.
Nuestra línea de producción se paró debido a un monitor Bently Nevada defectuoso. Lo encontramos en stock aquí y lo enviaron por DHL de inmediato. Volvió a funcionar en 48 horas, lo que realmente salvó nuestra planta.
Encontrar módulos nuevos y originales es fundamental para nuestra seguridad. Este equipo entrega componentes de fábrica con certificación completa. Su compromiso de vender únicamente productos nuevos los convierte en nuestro socio de mayor confianza.
Llevamos dos años abasteciendo aquí piezas de Honeywell y Schneider. Todos nuestros envíos llegan perfectamente embalados, con los precintos originales de fábrica intactos. Ofrecemos una comunicación clara y los mejores plazos de entrega del sector.