The Bently Nevada 330104-00-24-05-02-00, also cataloged as the 330104 Proximity Probe, operates as a dedicated hardware component for non-contacting displacement and vibration measurements within 3300 XL Proximity Transducer System platforms.
| Parameter | Specification |
|---|---|
| Model | 330104-00-24-05-02-00 |
| Brand | Bently Nevada |
| Origin | U.S.A. |
| Weight | 0.103 kg |
| Dimensions | 8 mm probe tip diameter, 240 mm case length, 1.0 meter total length |
| Operating Temp | -40 deg C to +85 deg C |
| Power Consumption | Driven by external Proximitor Sensor loop |
| Voltage Rating | 30 VDC |
| Current Rating | 10 mA |
| Cable Diameter | 5 mm |
| Protection Class | IP67 |
| Frequency Response | 10 Hz to 10 kHz |
| Sensitivity | 100 mV/g (integrated transducer baseline) |
| Dynamic Range | 0.1 g to 100 g |
| Mounting Type | M10 x 1 Thread |
The 330104-00-24-05-02-00 proximity probe utilizes high-frequency eddy currents to execute accurate non-contacting displacement measurements. Driven via an external 3300 XL Proximitor Sensor, it achieves standard eddy-current probe scaling to map target proximity into a linear voltage output. Proper field commissioning mandates precise gap voltage validation across the measurement path; technicians adjust the physical probe position relative to the shaft surface until the transducer output reads the designated -10 VDC targets, positioning the device at the exact midpoint of its linear envelope. This static gap calibration is required to capture dynamic rotor dynamics without clipping, while spatial isolation protocols ensure multi-channel cross-talk suppression between concurrent radial measurements on the same machinery shaft.
Q: What are the effects of physical cable damage on the 50 Ohm nominal loop impedance?
A: Any crimping or tearing of the 5 mm coaxial cable alters the dielectric constant and spacing between the core conductor and outer shield. This physical deformation degrades the loop impedance, corrupts the factory eddy-current scaling profile, and introduces tracking errors into the vibration output.
Q: Can this probe be connected directly to standard control system analog input cards without a Proximitor sensor?
A: No. The proximity probe is a passive inductive device that requires high-frequency RF excitation from a matched 3300 XL Proximitor Sensor to function. Direct connection to an analog input card will not provide power and yields zero signal output.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.