أصلي 100%. أكثر من 100,000 قطعة متوفرة. جاهزة للشحن.

  • ar

Configured for physical displacement measurement in 3300 XL transducer networks, the Bently Nevada 330703-000-070-10-02-00 (330703 Proximity Probe) provides direct physical/electrical execution.

Suffix Breakdown & Model Matrix

The part number 330703-000-070-10-02-00 designates specific physical properties based on the Bently Nevada ordering matrix:

  • 330703: Base designator for 3300 XL 11 mm Proximity Probe with M14 x 1.5 thread.
  • 000: Unthreaded length option designating 0 mm.
  • 070: Overall case length option designating 70 mm.
  • 10: Total cable length option specifying 10 meters (33 feet) configured for extended applications.
  • 02: Connector and cable-type option specifying standard cable with miniature coaxial ClickLoc connector.
  • 00: Agency approvals option indicating no agency approval is required.

Hardware Specifications

Parameter Specification
Model 330703-000-070-10-02-00
Brand Bently Nevada
Origin USA
Probe Tip Diameter 11.0 mm
Thread Type M14 x 1.5 thread
Input Voltage -17.5 VDC to -26 VDC
Output Resistance 50 Ohm
Operating Temp -51 to +177 deg C
Cable Armor Standard cable (without armor)
Connector Type Miniature coaxial ClickLoc
Dimensions 11.0 mm tip, 70 mm case length, 10 m cable
Net Weight 0.45 kg
Power Consumption Passive transducer sensor (0 W)

Eddy-Current Probe Scaling & Rotor Dynamics

This 11 mm probe operates via eddy-current physics to generate a dynamic electromagnetic field at the probe tip, measuring distance to a conductive target. To achieve the specified eddy-current probe scaling of 3.94 V/mm (100 mV/mil), this 10-meter probe is designed for extended applications and must be connected directly to a matched 3300 XL 11 mm Proximitor calibrated for a 10-meter system without intermediate extension cables. Proper physical installation and depth adjustment are required to ensure the correct gap voltage validation, targeting a baseline reading of -10 VDC at the center of the linear calibration envelope. This electrical stabilization is critical for tracking high-speed rotor dynamics and ensuring robust cross-talk suppression between closely mounted sensors.

Frequently Asked Questions

Q: Can this 10-meter total length probe be used with a standard 9-meter Proximitor?

A: No. Connecting a 10-meter probe to a 9-meter calibrated Proximitor creates an impedance mismatch. This mismatch alters the system calibration curve and will lead to inaccurate displacement and vibration measurements.

Q: Is an extension cable required for this specific configuration?

A: No. Because this probe option features an integrated 10-meter total cable length (Option 10), it connects directly to a 10-meter system Proximitor sensor, eliminating the need for an external extension cable.

Field Installation Guidelines

  • Mechanical Installation and Torque: Thread the probe body into the mounting port. Do not exceed 22.6 N-m (200 in-lb) of torque when tightening the mounting locknuts on the M14 x 1.5 threads to prevent physical damage to the internal casing.
  • Adjusting the Gap Voltage: Slowly rotate the probe toward the target surface while monitoring the Proximitor sensor output voltage. Secure the probe locknuts once the output registers the target gap voltage of -10.0 VDC (typically corresponding to a nominal physical gap of 2.0 mm or 80 mils for 11 mm systems).
  • Bending Radius and Cable Routing: Ensure the unarmored cable maintains a minimum bend radius of 25.4 mm (1.0 inch) during routing. Protect the ClickLoc coaxial connection using the integrated connector protector to isolate the signal path from machine ground.