100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

YOKOGAWA ABC11D-V2121 Bus Converter

The YOKOGAWA ABC11D-V2121, also cataloged as the ABC11D-V2121 bus converter, operates as a dedicated hardware component for bridging CENTUM CS 1000 RS-485 channels with Ethernet networks within Distributed Control System (DCS) architectures.

Hardware Specifications

Parameter Specification
Model ABC11D-V2121
Brand Yokogawa
Origin Japan
Weight 2 kg
Dimensions 200 mm x 150 mm x 50 mm
Operating Temp -10 deg C to +50 deg C
Power Consumption 15-20 W
Input 2 x Redundant RS-485 Channels
Output Ethernet (100 Mbps)

Process Control and Communication Connectivity

The ABC11D-V2121 utilizes a dual-redundant architecture to ensure continuous data transmission by maintaining synchronized primary and standby communication paths. The module manages the conversion between serial RS-485 interfaces and Ethernet-based networks, providing essential channel-to-channel isolation to preserve data integrity across the control backbone. Featuring a high-speed data processing capacity with a 1 Mbps serial input and 100 Mbps Ethernet output, the converter effectively manages network traffic in real-time. Automatic switchover logic triggers in less than 10 ms, ensuring fault-tolerant operation and preventing data loss in critical automation loops.

Frequently Asked Questions

Q: Does the ABC11D-V2121 require an external battery for configuration storage?

A: No. The unit utilizes non-volatile memory to retain all communication and network settings, eliminating the need for periodic battery maintenance or risk of configuration loss during power cycles.

Q: What is the significance of the 10 ms switchover time?

A: The 10 ms switchover threshold is designed to maintain deterministic communication performance. This latency ensures that the CENTUM CS 1000 control loops remain stable and do not detect a communication timeout during a primary path failure or during the hot-replacement of a redundant module.

Field Installation Guidelines

  • Mounting: Install the unit directly into standard Yokogawa I/O racks. Ensure the mounting surface is clean and that the module is properly seated to allow for optimal thermal heat dissipation through the chassis.
  • Fiber Optic Handling: When utilizing the optical fiber ports, verify that the connectors are free from dust or contaminants. Maintain the specified bend radius to prevent signal attenuation and preserve the 2 km maximum transmission range.
  • Wiring: Use shielded cables to connect the RS-485 channels. Terminate the shields at the designated cabinet ground point to prevent ground loops and minimize electromagnetic interference (EMI) ingress.
  • Diagnostics: Monitor the front-panel LED indicators during the initial power-up sequence to verify the status of the network connection and the synchronization state of the redundant paths.

¿Qué dicen nuestros clientes sobre nosotros?

Translation missing: es.general.search.loading