The Yokogawa AER4D-00 S1, also cataloged as the AER4D-00 Terminal Board, operates as a dedicated hardware component for Resistance Temperature Detector (RTD) signal termination within Yokogawa CENTUM VP distributed control systems. Configured as a 16-channel interface panel, the board routes RTD temperature telemetry directly to AAR145 input modules via AKB335 signal cables. The physical layout incorporates M4 screw terminals arranged in single or dual redundant module configurations, isolating field sensor wires and transferring digitized temperature data across the FIO node backplane architecture.
| Parameter | Specification |
|---|---|
| Model | AER4D-00 S1 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 1.5 kg |
| Dimensions | 482.6 mm W x 440 mm H x 88.1 mm D |
| Operating Temp | -20 to +60 deg C |
| Power Consumption | Passive termination board (0 W) |
| Channel Capacity | 16 RTD channels |
| Terminal Configuration | M4 screw terminals |
| Compatible Modules | AAR145 RTD Input Module |
| Compatible Cable | AKB335 Cable Assembly |
| Insulation Resistance | 100 Mohm minimum at 500 V DC |
| Withstanding Voltage | 1500 V AC for 1 minute (between commons); 2300 V AC for 1 minute (signal to case) |
| Rack Mounting | 19-inch rack mounting via 2 M5 screw holes |
The AER4D-00 S1 maintains stable signal conversion thresholds for 16 discrete RTD channels by preserving constant lead resistance balances across its terminal array. High isolation boundaries (100 Mohm at 500 V DC) prevent field potential differences from degrading low-voltage millivolt signals, ensuring accurate temperature processing when integrating CJC (cold junction compensation) values or passing variables across FOUNDATION Fieldbus / Profibus PA field networks. Dual-redundant wiring layouts support dual AAR145 modules, sustaining continuous temperature tracking and uninterrupted DCS database register updates if a primary signal path fails.
Q: How is galvanic isolation maintained between channel groups on the terminal board?
A: The board provides physical isolation designed to withstand 1500 V AC for 1 minute between commons (separated every 8 channels) and 2300 V AC for 1 minute between signal paths and the metal chassis frame.
Q: Can the AER4D-00 S1 board be mounted in standard 19-inch equipment racks?
A: Yes. The board features standard 19-inch rack dimensions (482.6 mm width) and mounts securely using two M5 screw holes on the mounting ears.
Q: What cable assembly is required to connect the terminal board to the AAR145 module?
A: Field connection requires the Yokogawa AKB335 multi-conductor signal cable, which plugs directly into the interface connectors on the terminal board.
Nuestra línea de producción se paró debido a un monitor Bently Nevada defectuoso. Lo encontramos en stock aquí y lo enviaron por DHL de inmediato. Volvió a funcionar en 48 horas, lo que realmente salvó nuestra planta.
Encontrar módulos nuevos y originales es fundamental para nuestra seguridad. Este equipo entrega componentes de fábrica con certificación completa. Su compromiso de vender únicamente productos nuevos los convierte en nuestro socio de mayor confianza.
Llevamos dos años abasteciendo aquí piezas de Honeywell y Schneider. Todos nuestros envíos llegan perfectamente embalados, con los precintos originales de fábrica intactos. Ofrecemos una comunicación clara y los mejores plazos de entrega del sector.