The TC-OAH061 is an authoritative high-level Analog Output Module designed for the Honeywell Experion Series-A I/O family. This module is a mechanical necessity for precise process control, providing six independent 4–20 mA current loops to drive critical field actuators, such as control valves, dampers, and variable speed drive (VSD) references. Engineered for high-availability environments like refineries and chemical processing plants, the TC-OAH061 features individual galvanic isolation for each channel, protecting the system backplane from electrical noise and field-side transients. Its robust construction ensures trustworthy signal delivery in the 24/7 demanding cycles of modern distributed control systems (DCS).
| Attribute | Details |
| Manufacturer | Honeywell |
| Model Number | TC-OAH061 |
| Part Number | 96978274-A01 |
| Product Type | Analog Output Module (AO) |
| System Compatibility | Experion Series-A I/O, TPS, TDC 3000 |
| Number of Channels | 6 Galvanically Isolated Channels |
| Output Signal Range | 4–20 mA DC |
| Resolution | 12-bit or higher D/A conversion |
| Accuracy | ±0.1% of Full Scale |
| Isolation | Channel-to-channel and channel-to-system isolation |
| Operating Temperature | 0 °C to +60 °C (32 °F to 140 °F) |
| Humidity | 5% to 95% Non-condensing |
| Dimensions | 96 × 96 × 48 mm |
| Weight | 0.5 kg (1.1 lbs) |
| Certifications | CE, TUV, UL508, CSA Compliance |
Module Alignment: Locate a compatible Series-A I/O slot in the Experion chassis. Align the TC-OAH061 with the guide rails and slide the unit inward until the backplane connectors are fully engaged.
Mechanical Securing: Tighten the integrated faceplate screws to the chassis frame. This step is an authoritative requirement to ensure electrical grounding and to prevent accidental disconnection during operation.
Field Wiring Termination: Connect the field actuator loops (valves/actuators) to the corresponding IOTA (Input Output Termination Assembly) terminals. Use shielded twisted pair cabling to maintain signal integrity over long distances.
Redundancy Configuration: If deploying in a redundant pair, ensure the secondary TC-OAH061 is correctly addressed and synchronized via the Experion Control Builder software to facilitate automatic failover.
Verification: Perform a loop check by commanding a 0%, 50%, and 100% output (4mA, 12mA, 20mA) from the Global User Station (GUS). Verify that the physical valve position or actuator response aligns precisely with the commanded value.
What are the primary benefits of galvanic isolation in the TC-OAH061?
Galvanic isolation is a mechanical necessity for protecting sensitive DCS logic from high-voltage transients on the field side. It prevents ground loops between different field actuators, ensuring that a fault on one channel does not degrade the performance of the other five channels or the main controller.
Is the TC-OAH061 suitable for legacy TDC 3000 systems?
Yes. The TC-OAH061 is an authoritative bridge component, compatible with Experion Series-A I/O which was designed to integrate seamlessly with both legacy TPS/TDC 3000 architectures and modern Experion PKS environments.
How does the module handle a lost communication signal?
Upon loss of backplane communication, the TC-OAH061 can be configured to "Hold Last Value" or "Go to Safe State" (e.g., 4mA). This ensures the plant remains in a trustworthy and predictable condition during a control failure.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.