100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Configured for power conversion and control-level signal monitoring in EX2000 and AC2000/DC2000 drive systems, the GE DS200DCFBG1B (DS200DCFB Power Supply Board) provides direct physical/electrical execution.

Suffix Breakdown & Model Matrix

  • DS200: Standard domestic base catalog prefix for GE drive system printed circuit board assemblies.
  • DCFB: Functional acronym designating the DC Power Supply Feedback Board layout.
  • G1: Group 1 functional production variant classification.
  • B: Revision iteration level B.

Hardware Specifications

Parameter Specification
Model DS200DCFBG1B
Brand GE (General Electric)
Origin USA
Operating Temp 0 to 60 deg C
Power Consumption System CPT transformer driven
Product Type DC Power Supply Feedback Board
Series Compatibility EX2000, DC2000, CB2000, FC2000, GF2000, ME2000, AC2000
AC Input Power 38 VAC and 115 VAC (or 24 VDC option)
Regulated DC Outputs +5 VDC, +/-15 VDC, +/-24 VDC
Auxiliary Output 115 VAC for enclosure cooling fans
Monitoring Functions Armature current/voltage, Field current, AC line voltage/phase sequence

Backplane Bus Communication Velocity & I/O Density Scaling

The DS200DCFBG1B provides deterministic control-level DC power distribution to connected card racks, stabilizing backplane bus communication velocity across high-speed drive processing loops. Dynamic monitoring circuits track AC line voltage magnitude, phase sequence, motor field current, and armature feedback parameters, passing processed metrics to primary drive regulators. Integrated driver circuits generate gate firing pulses for motor field SCR modules, preventing backplane bus distortion and ensuring firmware flash compatibility with upstream control modules.

Frequently Asked Questions

Q: What power rails does the DS200DCFBG1B generate for drive control circuits?

A: The board converts CPT transformer inputs to generate regulated +5 VDC, +/-15 VDC, and +/-24 VDC control-level supplies, along with a 115 VAC tap for cabinet cooling fans.

Q: Which operational feedback signals are actively monitored on the DCFB board?

A: The board features real-time monitoring circuitry for AC line current, AC line voltage magnitude, phase sequence, motor field current, and armature current/voltage parameters.

Field Installation Guidelines

  1. Lock out and isolate all primary high-voltage AC feeds and control power transformers (CPT) supplying the drive cabinet before servicing.
  2. Confirm complete de-energization across power input terminals using a calibrated voltage meter.
  3. Wear a grounded ESD wrist strap throughout handling to prevent static discharge to onboard semiconductors and regulator components.
  4. Align edge guides and slide the module securely into place, ensuring all screw terminals and ribbon cable headers are firmly seated.
  5. Verify line-to-line phase sequencing and CPT input voltage taps match manual GEI-100028 specifications before applying power.