100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

The Bently Nevada 330905-00-10-05-02-00 serves as the primary 330905 Proximity Sensors utilized to execute non-contact shaft displacement and vibration measurement across 3300 NSv Machinery Monitoring System platforms. The transducer integrates an M10 x 1 AISI 304 stainless steel threaded body with 0 mm unthreaded length, 100 mm overall case length, and a 0.5 m (20 in) standard coaxial cable terminated with a miniature coaxial ClickLoc connector.

Suffix Breakdown & Model Matrix

Option Code Parameter Designation Selected Configuration
330905 Base Model 3300 NSv Probe, M10 x 1 thread, without armor
-00 Unthreaded Length 0 mm
-10 Overall Case Length 100 mm
-05 Total Length Option 0.5 m (20 in)
-02 Connector & Cable Type Miniature coaxial ClickLoc connector, standard cable
-00 Agency Approval Option Not required

Hardware Specifications

Parameter Specification
Model 330905-00-10-05-02-00
Brand Bently Nevada
Origin United States
Weight 1.5 kg
Dimensions M10 x 1 thread profile (100 mm overall case length)
Operating Temp -34 deg C to +177 deg C (-30 deg F to +351 deg F)
Power Consumption Passive transducer (Powered via Proximitor Sensor)
Storage Temperature -51 deg C to +177 deg C (-60 deg F to +351 deg F)
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 304 stainless steel (SST)
Unthreaded Length 0 mm
Overall Case Length 100 mm
Total Cable Length 0.5 m (20 in)
Connector Type Miniature coaxial ClickLoc connector
Agency Approvals Not required (Option 00)

Mechanical Monitoring & TSI Performance

Operating on high-frequency eddy-current sensing mechanisms, the 330905-00-10-05-02-00 transducer evaluates real-time rotor dynamics on small-diameter shafts or constrained counterbores where standard probe clearances are insufficient. Paired with a matching 3300 NSv Proximitor Sensor, precise eddy-current probe scaling generates a continuous voltage output proportional to target distance. Achieving gap voltage validation targeted at -10 VDC during physical installation ensures operation at the center of the calibrated linear range, optimizing displacement sensitivity and cross-talk suppression in dense multi-channel monitor installations.

Frequently Asked Questions

Q: What gap voltage reading confirms correct positioning during mechanical installation of the 330905 probe?

A: Adjust probe insertion until the output voltage measured from the associated 3300 NSv Proximitor Sensor registers -10 VDC, centering the signal within its dynamic linear range.

Q: Can the 0.5 m probe cable be connected directly to the monitoring system backplane terminal strip?

A: No. The integrated 0.5 m (20 in) probe cable must connect to a 3300 NSv extension cable to establish the complete calibrated system length (5.0 m or 7.0 m) required by the Proximitor Sensor.

Q: What tip construction material is utilized to maintain mechanical integrity at high operating temperatures?

A: The probe tip is molded from Polyphenylene sulfide (PPS), paired with an AISI 304 stainless steel case rated for continuously elevated operating conditions up to +177 deg C.

Field Installation Guidelines

  1. Thread the M10 x 1 stainless steel casing into the mounting port by hand, taking care not to cross-thread or over-torque the assembly.
  2. Maintain a minimum of 5 full threads of engagement to secure the casing against high-frequency shaft and housing vibration.
  3. Keep the coaxial cable free of sharp radii and separate from high-voltage AC lines to prevent signal distortion or mechanical damage.
  4. Clean all ClickLoc coaxial connector surfaces thoroughly prior to mating, verifying that the locking mechanism engages completely.

¿Qué dicen nuestros clientes sobre nosotros?