Configured for Ethernet signal conversion and V Net bus regeneration in Yokogawa CENTUM VP, CS 3000, and FA-M3 platforms, the Yokogawa YNT512D-P11/KT (YNT512D Ethernet Interface & Bus Repeater Module) provides direct physical execution.
| Suffix / Option | Option Code | Description |
|---|---|---|
| YNT512D | Base Model | Ethernet interface and dual-redundant V Net bus repeater chassis |
| -P11/KT | Option Variant | Rack-mounted FA-M3 interface variant with cable tray assembly |
| -V12 | Option Variant | Extended thermal range variant operating up to 55 deg C |
| -Q12 | Option Variant | Compact bus repeater module assembly |
| Parameter | Specification |
|---|---|
| Model | YNT512D-P11/KT |
| Brand | Yokogawa |
| Origin | USA |
| Weight | 0.3 kg to 3.36 kg (variant dependent) |
| Dimensions | 144 mm x 144 mm x 72 mm |
| Operating Temp | 0 deg C to 50 deg C (-P11/KT variant) |
| Power Consumption | 4.5 W (-V12 variant) |
| Power Supply Input | 100-240 V AC (50/60 Hz) or optional 24 V DC +/-5% |
| Network Interface | 10BASE-T / 100BASE-TX (IEEE 802.3 compliant) |
| Network Protocols | TCP/IP, UDP/IP, proprietary V Net protocol |
| Diagnostic Port | RS-232C serial configuration interface |
| Channel Density | 2 input channels for signal regeneration |
| Ingress Protection | IP65 rated enclosure (select variants) |
| System Compatibility | Yokogawa CENTUM VP, CS 3000, FA-M3 controllers |
The YNT512D-P11/KT module routes network packets between Ethernet controllers and proprietary V Net buses while maintaining physical channel-to-channel isolation across node segments. Active driver circuitry regenerates incoming signal waveforms, suppressing common-mode line noise and high-frequency noise induced by surrounding field instruments. Internal optocoupler barriers isolate internal CPU backplane logic from long-distance coaxial and twisted-pair bus trunks, preventing ground potential offsets from corrupting deterministic control data.
Q: Does the hot-swap capability of the module require powering down connected V Net bus segments?
A: Field technicians can replace the module online without disconnecting system power or disturbing adjacent nodes, provided the secondary V Net bus carries active communication traffic during hot insertion.
Q: How does the module process event transmission data frames across Ethernet interfaces?
A: The onboard network controller handles up to 128 bytes per event transmission, processing both ASCII and binary data structures over TCP/IP or UDP/IP protocols at standard 10/100 Mbps communication speeds.
Position the YNT512D-P11/KT module on the designated rack assembly or DIN-rail track. Engage the module mounting latches completely, then torque front retaining screws to ensure proper grounding contact with the cabinet frame.
Connect primary and secondary V Net communication cables to their respective module ports. Keep signal lines separated from high-voltage AC distribution power cables, and ground all cable shield drain wires at a single ground bus bar within the control enclosure.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.