Configured for high-reliability backplane power distribution in Modicon Quantum PLC platforms, the Schneider Electric 140CPS11420 (140CPS11420 Summable Power Supply) provides stable 5.1 VDC output for CPU, communication, and I/O modules via a summable, redundant-capable architecture.
| Parameter | Specification |
|---|---|
| Model | 140CPS11420 |
| Brand | Schneider Electric |
| Origin | Not specified |
| Weight | 0.65 kg |
| Dimensions | Standard Quantum Form Factor |
| Operating Temp | Not specified |
| Input Voltage | 115 VAC (93–132 V) / 230 VAC (170–276 V) |
| Output Voltage | 5.1 VDC |
| Output Current | 11 A (Standalone) / 20 A (Summable) |
| Isolation | 1500 VAC (Primary to Secondary) |
The 140CPS11420 utilizes a summable architecture allowing for parallel operation, effectively increasing the total current capacity to 20 A or facilitating N+1 redundancy. When installed in a redundant-capable backplane, the modules share the power load, ensuring that the system remains energized if an individual unit fails. Each module includes integrated overvoltage and overload protection circuits, providing a fault-tolerant environment for process control equipment. The 1 NC dry contact output allows for immediate alarm signaling to the controller in the event of an internal power fault, facilitating proactive maintenance.
Q: How is the "summable" capacity of 20 A achieved when using two units?
A: When two 140CPS11420 units are installed in a redundant-capable Quantum backplane, the backplane circuitry manages the parallel load sharing. The modules are physically and electrically synchronized to combine their current output, resulting in a total capacity of 20 A while maintaining voltage stability at 5.1 VDC.
Q: What action should be taken if the "Power OK" LED turns off during operation?
A: An off LED indicates either an input power loss or an internal module failure. Check the AC input voltage levels against the specified operating ranges (93–132 V or 170–276 V). If the input is within tolerance, check the status of the NC dry contact relay; if the contact is open (indicating a fault), the module must be replaced according to system safety protocols.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.