The Yokogawa ARM55C-000, also cataloged as the ARM55C Mechanical Relay Output Board, operates as a dedicated hardware component for high-density dry-contact signal switching and electrical load isolation within CENTUM VP platforms. The board conditions 24 VDC control signals into 32 independent relay outputs to drive field actuators, solenoids, and interposing circuits across FIO subsystems.
| Parameter | Specification |
|---|---|
| Model | ARM55C-000 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 1.2 kg |
| Dimensions | 250 x 150 x 50 mm |
| Operating Temp | -10 to 55 deg C |
| Storage Temp | -20 to 70 deg C |
| Operating Humidity | 5 to 85% RH (non-condensing) |
| Power Supply | 24 VDC nominal (0.85 A max) |
| Power Consumption | 12 W typical (all relays energized) |
| Number of Channels | 32 dry-contact mechanical relay outputs |
| Contact Configuration | Selectable Form-A (NO) or Form-B (NC) |
| Maximum Load Rating | 2 A at 250 VAC / 2 A at 30 VDC / 0.1 A at 125 VDC |
| Minimum Load Rating | 10 mA at 5 VDC |
| Initial Contact Resistance | <= 100 mohm |
| Insulation Resistance | >= 10 Mohm at 500 VDC |
| Response Time | <= 15 ms (energize), <= 10 ms (de-energize) |
| Mechanical Life | 10,000,000 operations |
| Electrical Life | 50,000 operations at rated load |
| Status Indicators | 32 red channel LEDs |
| Mounting Type | Backplane or DIN-rail (with adapter) |
| Certifications | CE, UL, CSA |
The ARM55C-000 features true mechanical relay galvanic isolation between internal low-voltage control logic and high-power field-side wiring. Each of the 32 channels operates via dry contacts, preventing high-voltage surges, transient spikes, and inductive field noise from coupling back to the CENTUM VP backplane bus. When integrated with analog temperature networks, the board provides clean digital switching paths that prevent ground potential offsets from degrading cold junction compensation (CJC) accuracy on adjacent thermocouple input cards. Internal 24 VDC coil distribution circuits include reverse-polarity protection to maintain stable contact actuation during heavy switching loads.
Q: How are individual outputs configured between Normally Open (NO) and Normally Closed (NC) modes on the ARM55C-000?
A: Technicians select Form-A (NO) or Form-B (NC) contact logic per channel by setting physical jumpers or wiring output conductors to the designated NO/NC terminal points on the terminal block assembly, enabling precise alignment with field fail-safe logic requirements.
Q: What are the electrical limitations when switching inductive DC loads with the ARM55C-000 relays?
A: While the contacts support resistive loads up to 2 A at 30 VDC, switching inductive DC loads (such as heavy solenoid valves) reduces contact lifespan due to arc erosion. Installers must fit external freewheeling flyback diodes or RC snubber networks directly across field inductive loads to suppress back-EMF spikes and preserve the 50,000-operation electrical life rating.
Mount the ARM55C-000 securely onto its backplane chassis or standard DIN-rail using compatible mounting hardware, ensuring solid earth grounding through the metal mounting structure. Strip field output wires to specified gauge standards and land conductors onto pressure clamp terminals, tightening screws to avoid high-resistance terminations. Separate field-side AC power distribution cables from low-voltage DC control signal harnesses to prevent electromagnetic interference. Ensure cabinet thermal convection provides adequate ventilation so ambient operating temperatures remain between -10 and 55 deg C under full 32-channel continuous load operationYokogawa ARM55C-000 Relay Output Board
The Yokogawa ARM55C-000, also cataloged as the ARM55C Mechanical Relay Output Board, operates as a dedicated hardware component for high-density dry-contact signal switching and electrical load isolation within CENTUM VP platforms. The board conditions 24 VDC control signals into 32 independent relay outputs to drive field actuators, solenoids, and interposing circuits across FIO subsystems.
| Parameter | Specification |
|---|---|
| Model | ARM55C-000 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 1.2 kg |
| Dimensions | 250 x 150 x 50 mm |
| Operating Temp | -10 to 55 deg C |
| Storage Temp | -20 to 70 deg C |
| Operating Humidity | 5 to 85% RH (non-condensing) |
| Power Supply | 24 VDC nominal (0.85 A max) |
| Power Consumption | 12 W typical (all relays energized) |
| Number of Channels | 32 dry-contact mechanical relay outputs |
| Contact Configuration | Selectable Form-A (NO) or Form-B (NC) |
| Maximum Load Rating | 2 A at 250 VAC / 2 A at 30 VDC / 0.1 A at 125 VDC |
| Minimum Load Rating | 10 mA at 5 VDC |
| Initial Contact Resistance | <= 100 mohm |
| Insulation Resistance | >= 10 Mohm at 500 VDC |
| Response Time | <= 15 ms (energize), <= 10 ms (de-energize) |
| Mechanical Life | 10,000,000 operations |
| Electrical Life | 50,000 operations at rated load |
| Status Indicators | 32 red channel LEDs |
| Mounting Type | Backplane or DIN-rail (with adapter) |
| Certifications | CE, UL, CSA |
The ARM55C-000 features true mechanical relay galvanic isolation between internal low-voltage control logic and high-power field-side wiring. Each of the 32 channels operates via dry contacts, preventing high-voltage surges, transient spikes, and inductive field noise from coupling back to the CENTUM VP backplane bus. When integrated with analog temperature networks, the board provides clean digital switching paths that prevent ground potential offsets from degrading cold junction compensation (CJC) accuracy on adjacent thermocouple input cards. Internal 24 VDC coil distribution circuits include reverse-polarity protection to maintain stable contact actuation during heavy switching loads.
Q: How are individual outputs configured between Normally Open (NO) and Normally Closed (NC) modes on the ARM55C-000?
A: Technicians select Form-A (NO) or Form-B (NC) contact logic per channel by setting physical jumpers or wiring output conductors to the designated NO/NC terminal points on the terminal block assembly, enabling precise alignment with field fail-safe logic requirements.
Q: What are the electrical limitations when switching inductive DC loads with the ARM55C-000 relays?
A: While the contacts support resistive loads up to 2 A at 30 VDC, switching inductive DC loads (such as heavy solenoid valves) reduces contact lifespan due to arc erosion. Installers must fit external freewheeling flyback diodes or RC snubber networks directly across field inductive loads to suppress back-EMF spikes and preserve the 50,000-operation electrical life rating.
Mount the ARM55C-000 securely onto its backplane chassis or standard DIN-rail using compatible mounting hardware, ensuring solid earth grounding through the metal mounting structure. Strip field output wires to specified gauge standards and land conductors onto pressure clamp terminals, tightening screws to avoid high-resistance terminations. Separate field-side AC power distribution cables from low-voltage DC control signal harnesses to prevent electromagnetic interference. Ensure cabinet thermal convection provides adequate ventilation so ambient operating temperatures remain between -10 and 55 deg C under full 32-channel continuous load operation.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.