The Foxboro FBM201 RH914SQ, also cataloged as the FBM201 Analog Input Interface Module, operates as a dedicated hardware component for multi-channel analog signal acquisition within Foxboro 200 Series I/O subsystem networks. The module executes high-accuracy sigma-delta data conversions for field sensor loops and transfers digitized values across redundant module Fieldbus communication lanes.
| Parameter | Specification |
|---|---|
| Model | FBM201 RH914SQ (Includes P0914SQ variants) |
| Brand | Foxboro (by Schneider Electric) |
| Origin | USA |
| Weight | 0.284 kg (Module only) |
| Dimensions | 10.4 cm x 4.5 cm x 11.4 cm |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | 7 W (Maximum) |
| Input Channels | 8 isolated and independent channels |
| Input Range | 0 to 20 mA dc (Standard FBM201 variant) |
| Signal Conversion | 16-bit sigma-delta A/D conversion per channel |
| Heat Dissipation | 3 W (Maximum) |
| Relative Humidity | 5 to 95% (Noncondensing) |
| Environmental Limits | Class G3 harsh environments; Altitude -300 to +12,000 m |
| Communication | Redundant 2 Mbps module Fieldbus |
The FBM201 subassembly implements strict per-channel galvanic isolation, separating each of the 8 analog input signals from all adjacent circuits and the system reference ground. This prevents loop errors caused by common-mode voltages and ground loops within active 4-20 mA HART loop protocol lines.
The onboard processor executes dedicated analog input application programs that manage conversion timing, configuration parameters for integration intervals, and Rate of Change Limits. Bus communications interface with corresponding Fieldbus Communication Modules (FCM) or Fieldbus Control Processors (FCP) via the 2 Mbps backplane interface, enabling fast data refreshes without requiring external software calibration.
Q: Can the FBM201 be removed from the baseplate while the 200 Series system is under power? A: Yes. The module features a hot-swapping hardware design. It can be inserted or extracted from its modular baseplate without interrupting the communication integrity of the redundant 2 Mbps Fieldbus or disrupting adjacent active modules.
Q: Does the FBM201 provide loop power for 2-wire field transmitters? A: The FBM201 itself acts as an isolated measurement interface. Loop power distribution to internally or externally powered field transmitters is managed through the companion Termination Assemblies (TAs) assigned to the specific field wiring framework.
Q: What is the purpose of the configurable integration time on this module? A: The integration time allows the sigma-delta converters to reject power line frequency noise and transient EMI. Industrial technicians can configure these parameters to optimize rejection levels for 50 Hz or 60 Hz background interference.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.