100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Product Overview

The Honeywell FC-TSGASH-1624P serves as a high-integrity physical interface between discrete field devices and the central safety controller. Engineered specifically for the Honeywell Safety Manager and Fail Safe Control (FSC) platforms, this 16-channel Field Termination Assembly (FTA) handles critical ON/OFF signal transmissions for monitoring and actuation. We provide this unit as 100% Brand New and Original, ensuring your Safety Instrumented System (SIS) utilizes factory-certified hardware to maintain peak operational uptime and regulatory compliance.

Technical Specifications

Feature Specification Details
Manufacturer Honeywell
Model Number FC-TSGASH-1624P
Product Type Digital I/O Field Termination Assembly (FTA)
Channel Count 16 Discrete Channels
Operating Voltage 24 VDC Nominal
Logic Thresholds High: >15VDC; Low: <4VDC
Protection Architecture Individual per-channel current limiting
Isolation Channel-to-Bus Galvanic Isolation
Mounting Style Standard DIN EN rail (Universal snap-in)
Operating Temperature –40 °C to +70 °C
Compliance CE, UL, IEC; Suitable for Class I, Div 2
Weight 0.45 kg

Engineering Advantages

  • Localized Short-Circuit Protection: The FC-TSGASH-1624P utilizes an individual current-limiting design for every channel. If a field-side sensor or actuator experience a short circuit, the board isolates that specific loop. This architecture prevents a singular fault from collapsing the 24VDC power rail for the remaining 15 channels, ensuring continuous system availability.

  • Galvanic Noise Immunity: High-grade galvanic isolation separates the field wiring from the sensitive system bus. This barrier blocks electrical transients, electromagnetic interference (EMI), and ground loops from reaching the safety processor, maintaining the integrity of the logic execution in high-noise industrial environments.

  • Harsh Environment Readiness: This module carries an industrial temperature rating of –40 °C to +70 °C. Its ruggedized construction allows for reliable operation on offshore platforms, chemical processing plants, and desert refineries where unconditioned cabinets are common.

  • Rapid Status Diagnostics: Integrated LED indicators provide immediate visual feedback for each of the 16 channels. Technicians can identify signal states and fault conditions at a glance, significantly reducing Mean Time to Repair (MTTR) during critical maintenance windows.

  • Efficient Field Integration: Secure screw terminals handle rugged field wiring, while a specialized SIC Connector manages the high-speed system interface via SICC interconnect cables. This dual-connection strategy simplifies installation in crowded DIN rail enclosures and ensures vibration-resistant contacts.

FAQs

  • Can the FC-TSGASH-1624P handle both inputs and outputs? Yes. This module functions as a Digital Input/Output Field Termination Assembly, allowing it to interface with both discrete sensors (inputs) and actuators like solenoids or relays (outputs) within the Safety Manager environment.

  • Is this board compatible with legacy Honeywell FSC systems? Absolutely. The FC-TSGASH-1624P maintains full compatibility with both the legacy Fail Safe Control (FSC) systems and the modern Safety Manager and Safety Manager SC platforms.

  • Does this unit support hot-swapping? While the board itself is a passive termination assembly, it supports live maintenance procedures when used in conjunction with redundant Safety Manager I/O modules, provided you follow standard site-specific safety protocols.

  • What are the mounting requirements for Class I, Div 2 areas? The board is certified for Class I, Div 2 hazardous locations. You must install it within a suitable enclosure that meets the local electrical code and environmental protection requirements (IP/NEMA) for that specific hazardous zone.

What's clients say about us