The Foxboro F3-FBM202, also cataloged as the FBM202 Thermocouple Input Module, operates as a dedicated hardware component for direct temperature measurement and signal digitization within Foxboro I/A Series and Foxboro Evo platforms.
| Parameter | Specification |
|---|---|
| Model | FBM202 |
| Brand | Foxboro |
| Origin | USA |
| Weight | 0.35 kg |
| Dimensions | 45 x 105 x 115 mm |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | 7 W (Typical) |
| Input Channels | 8 isolated and independent channels |
| Input Signals | Thermocouples and Millivolt (mV) inputs |
| Measurement Accuracy | +/-0.1% of span (Typical) |
| Resolution | 16-bit A/D conversion |
| Isolation | Full channel-to-channel and channel-to-system isolation |
| Enclosure Protection | IP65 rating with G3 conformal coating |
| Power Input | 24 VDC redundant input support |
The module provides galvanic channel-to-channel isolation across all 8 input circuits to suppress common-mode noise and eliminate ground loop interference on millivolt-level field signals. When coupled with a field termination assembly equipped with a Cold Junction Reference (CJR), internal firmware algorithms automatically execute cold junction compensation (CJC) and non-linear thermocouple linearization. This processing maintains accurate 16-bit analog-to-digital signal conversion across extreme ambient fluctuations without requiring intermediate 4-20 mA transmitters or external conditioning hardware.
Q: Does the FBM202 require an external Cold Junction Reference (CJR) for thermocouple processing?
A: The module executes cold junction compensation automatically when wired to a compatible field termination assembly that incorporates an integrated CJR sensor element.
Q: What level of electrical isolation does the FBM202 provide between individual input channels?
A: The module features complete galvanic isolation between individual channels as well as between field-side input circuitry and the internal system backplane logic.
Q: Is the FBM202 capable of operating in redundant hardware configurations?
A: Yes, two FBM202 modules can be configured as a redundant pair on standard I/A Series baseplates to enable automatic failover protection without interrupting thermal data transfer.
Seat the module directly into its designated slot on the I/A Series baseplate or rack frame, ensuring the retention latches engage firmly to establish reliable backplane bus connection. Ensure the field enclosure maintains an IP65 ingress protection level and that ambient temperatures remain within the rated -40 to +70 deg C operating window.
Connect all thermocouple and millivolt signal pairs to the corresponding field termination assembly using dedicated extension wire. Route low-voltage thermocouple wiring away from high-voltage AC cables and switching drive conduits to avoid electromagnetic noise induction. Ground overall cable shields at a single ground bus point on the cabinet frame to preserve 16-bit signal integrity across all 8 channels.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.