100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

YOKOGAWA NT225AA-04 Power Supply Module

The YOKOGAWA NT225AA-04, also cataloged as the NT225AA Power Supply Module, operates as a dedicated hardware component for supplying regulated DC voltage and executing fault diagnostics within CENTUM VP, CS 3000, and ProSafe-RS control system networks.

Hardware Specifications

Parameter Specification
Model NT225AA-04
Brand Yokogawa
Origin USA
Weight 1.2 kg
Dimensions 130 x 45 x 245 mm
Operating Temp 0 to 55 deg C
Power Consumption ~120 VA
Input Voltage 100-120 VAC / 200-240 VAC (auto-switching)
Output Voltage 24 VDC +/-5%
Output Current 5 A
Efficiency >=85%
Humidity 10-90% RH (non-condensing)

Channel Isolation and Loop Power Integrity

Yokogawa DCS infrastructure requires robust channel-to-channel isolation and tight voltage stability to maintain signal integrity across analog I/O cards. The unit delivers a regulated 24 VDC output that shields sensitive controller electronics from line variations. When deployed in dual-redundant power configurations, internal diode-ORing mechanisms prevent back-feeding, while localized cold junction compensation (CJC) circuits on associated analog field buses remain unaffected by power-line ripple or sudden load shifts.

Frequently Asked Questions

Q: Does the module support hot-swapping during active system operation?

A: Yes. When configured in a dual-redundant rack alignment alongside a secondary unit, field technicians can safely extract and replace a faulted module without powering down the system rack or interrupting process loops.

Q: What protective measures prevent damage to connected system I/O modules during downstream fault conditions?

A: The module integrates active overvoltage, overcurrent, and short-circuit protection circuits. Upon detecting an output short or overcurrent state, the internal logic limits total output power to mitigate thermal damage and safeguard connected backplane buses.

Field Installation Guidelines

Mount the unit directly into the designated slot of the system chassis, ensuring the rear connector pins engage completely with the backplane bus. Field technicians must verify proper ground bonding by attaching a low-impedance copper drain wire from the enclosure ground point directly to the cabinet star-ground bar.

Maintain a minimum clearance of 50 mm above and below the module rack to facilitate natural convective cooling and prevent localized thermal buildup. Run AC power feeder cables in separate conduit pathways away from sensitive low-level analog I/O wiring to minimize electromagnetic interference across field loops.