The Foxboro P0916DC, also cataloged as the P0916DC Terminal Cable, operates as a dedicated hardware component for balancing digital communication lines within Foxboro I/A Series FBM2xx networks. It executes physical signal routing over a 3-meter fixed length to interface field transmitters to Fieldbus Modules, suppressing cross-talk in topologies utilizing a common external power supply.
| Parameter | Specification |
|---|---|
| Model | P0916DC |
| Brand | Foxboro (Invensys) |
| Origin | USA |
| Weight | 0.1 kg (1.01 lbs) |
| Dimensions | 2.2 cm x 12.4 cm x 12.6 cm |
| Operating Temp | -20 to +70 deg C |
| Power Consumption | 24 VDC Nominal (Loop Powered) |
| Cable Type | Type 1 Terminal Cable |
| Physical Length | 3 meters |
| Termination Type | Compression screw terminals |
| Analog Channels | 16 channels (4-20 mA, 0-10 VDC capability) |
| Communication Interfaces | RS-232, RS-485 (DB9 configurations), HART loop path |
| Isolation | 2500 Vrms optical isolation |
| Protocol Support | MODBUS RTU, ASCII, HART protocol |
The assembly incorporates a Balun module engineered to maintain line balance across 4-20 mA HART loop protocol paths when powered via an external power supply. This configuration isolates the common return path of multi-loop wiring, preventing the near-end cross-talk that occurs when field loops share common electrical points. The system enforces channel-to-channel isolation parameters up to the physical limitations of the 2500 Vrms optical isolation circuitry, preventing common-mode voltage spikes from disrupting backplane data packets.
Q: Is the P0916DC cable required if the HART transmitters are powered directly from the internal FBM power source?
A: No. Loops utilizing the FBM internal power source maintain independent electrical isolation and do not experience the common-connection cross-talk caused by external power supplies. The line-balancing Balun function of the P0916DC is only active and necessary when field loops share a common external power supply line.
Q: Can the 3-meter physical length of this Type 1 cable be modified or spliced in the field?
A: No. Altering the physical length of the Type 1 cable modifies the impedance parameters calibrated for the Balun module. Splicing can introduce noise, alter signal attenuation, and degrade the 2500 Vrms optical isolation threshold.