Configured for centralized electrical distribution in DCS control cabinet architectures, the Yokogawa PDB/16 (PDB/16 Power Distribution Board) provides direct physical and electrical execution of power routing to field I/O modules.
| Parameter | Specification |
|---|---|
| Model | PDB/16 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 1 kg |
| Dimensions | Standard Rack-Mount Format |
| Operating Temp | Industrial Standard Range |
| Power Consumption | Variable per Load |
| Channels | 16 independent output channels |
| Input Voltage | 24 VDC or 220-240 VAC |
| Protection | Overcurrent and short-circuit isolation |
The PDB/16 maintains stable voltage delivery across Yokogawa CENTUM VP and CS 3000 platforms through dedicated channel-to-channel isolation. This configuration mitigates the risk of voltage spikes propagating between independent I/O loops, ensuring that sensitive signal conditioning remains unaffected by power fluctuations. The board architecture supports standard 4-20 mA HART loop protocol power requirements, ensuring that connected instrumentation maintains consistent loop current. Proper distribution depends on maintaining a low-impedance connection to the central ground bus, which prevents noise coupling into the logic circuitry of the DCS modules.
Q: Does the PDB/16 support hot-swapping of output channels?
A: No. The PDB/16 serves as a static power distribution interface. Any disconnection or modification of output wiring must be performed after isolating the input voltage to prevent arcing and potential damage to the distribution bus.
Q: How do the diagnostic LEDs indicate a short-circuit fault?
A: The PDB/16 features per-channel status LEDs. A darkened LED while the main power bus is energized signifies either an open circuit or that the internal overcurrent protection for that specific channel has tripped. Resetting requires physical inspection of the field wiring.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.