Configured for field signal termination and remote control execution in CENTUM VP and CS 3000 DCS platforms, the YOKOGAWA RC1*A (RC1A Remote I/O Module) provides direct physical/electrical execution of sensor-to-controller signal interface management.
| Parameter | Specification |
|---|---|
| Model | RC1*A |
| Brand | YOKOGAWA |
| Origin | Japan |
| Weight | 1.5 kg |
| Dimensions | 254 × 152 × 127 mm |
| Operating Temp | -20 deg C to +70 deg C |
| Power Consumption | 24 V DC |
| I/O Type | Remote I/O (Analog/Digital) |
| Isolation | Electrical |
| Protection | Built-in Surge Suppression |
The RC1*A executes high-speed signal processing between field instrumentation and the DCS backplane. To ensure data consistency across distributed networks, the module supports Modbus RTU and Modbus TCP communication protocols, allowing for deterministic data exchange. Channel-to-channel isolation is integrated within the signal path to prevent ground-loop interference and common-mode transients. Furthermore, the module facilitates cold junction compensation (CJC) for integrated temperature inputs, ensuring that terminal temperature fluctuations do not impact the precision of the connected instrumentation. Continuous self-diagnostics monitor the integrity of the input channels, providing proactive fault detection before signal degradation occurs.
Q: Does the RC1*A support hot-swapping within the DCS rack? A: Module replacement must be performed in accordance with the specific system power-down sequence. Always verify the status of the redundant controller and communication bus before disconnecting the module to prevent backplane bus errors.
Q: Are the Modbus RTU and TCP protocols mutually exclusive on this module? A: The module architecture supports concurrent protocol handling; however, confirm the specific channel configuration mapping to ensure that digital data frames are correctly routed to the intended communication registers.
Q: How is the output current limit managed during actuator control? A: The module is rated for a continuous output current of 1 A. Over-current protection circuitry is active; ensure the connected load impedance does not exceed the power supply limits to prevent thermal shutdown of the output channel.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.