TRICONEX 9853-610 Tricon V9/V10 Series Terminal Board

The TRICONEX 9853-610, also cataloged as the 9853-610 Termination Panel, operates as a dedicated hardware component for field signal distribution within Tricon V9/V10 Series SIS racks. The board routes field-derived analog output current loops from centralized control cards to direct-wired actuators and validation circuits.

Hardware Specifications

Parameter Specification
Model 9853-610
Brand TRICONEX (Schneider Electric)
Origin United States (or per manufacturer allocation)
Weight 1.5 - 2.0 kg
Dimensions 177.8 mm x 101.6 mm x 228.6 mm
Operating Temp -20 to +60 deg C
Power Consumption 15 W typical
Panel Type Current output, basic
Active Points 8
Compatible Modules 2870H (HART analog output), 3805E/H (4-20 mA TMR)
Termination Style Screw-clamp terminals, accepts 12-22 AWG wire
Isolation 1500 VAC galvanic isolation between backplane and field wiring
Safety Integrity Level SIL3 (IEC 61508 / IEC 61511)
Storage Temp -40 to +85 deg C
Humidity Range 5% to 95% non-condensing
Certifications IEC 61508 SIL3, TÜV, CE, UL Class I Div 2, ATEX Zone 2

Triple Modular Redundancy and Safety Integrity

The termination panel architecture supports a fault-tolerant interface configuration built for triple modular redundancy (TMR) 2oo3 systems. Galvanic isolation rated at 1500 VAC separates the field loops from the primary backplane, protecting the core processing logic against transient overvoltages and grounding noise. The internal track design routes parallel signals from compatible 2870H or 3805E/H TMR modules down to individual screw-clamp fields, achieving continuous fail-safe state execution through dedicated diagnostic paths that prevent a single field wiring short from failing the overall instrumentation loop.

Frequently Asked Questions

Q: Which explicit interface modules can interface with the 9853-610 terminal board assembly?

A: The board interfaces directly with module part number 2870H (an 8-point HART analog output interface module) and module part number 3805E/H (an 8-point, 4-20 mA commoned-return, DC-coupled TMR analog output module).

Q: What grounding and physical isolation boundaries must be maintained during installation?

A: The board provides up to 1500 VAC galvanic isolation between the field wiring terminals and the control backplane logic. For operation, field teams must maintain independent cable shielding loops bonded directly to a low-impedance master ground to prevent spurious trips during module hot-swap actions.

Field Installation Guidelines

Mount the termination board securely inside the Tricon V9/V10 chassis enclosure using designated DIN-rail or backplane bracket anchors. Ensure the interface cables from the 2870H or 3805E/H modules are locked completely into the panel input header sockets. Terminate all field cabling using the on-board screw-clamp terminals, keeping within the supported 12-22 AWG wire spectrum. Ground the external instrument shielding drain wires at the unified enclosure grounding bar to control electromagnetic interference (EMI). Route the 4-20 mA active current loops through isolated high-density wire ducts separated by physical barriers from any raw AC mains power conductors.