The TRICONEX AI3351, also cataloged as the TRICONEX 3351 Analog Input Module, operates as a dedicated hardware component for converting field analog signals into digital values within Tricon SIS platforms. This hardware element samples analog currents from field transmitters and provides digital representations to the main processing units. The module manages input signal filtering and digitizes the electrical values via independent internal conversion circuits.
| Parameter | Specification |
|---|---|
| Model | AI3351 |
| Brand | TRICONEX (Schneider Electric) |
| Origin | USA |
| Weight | 1.5 kg (4.10 lbs) |
| Dimensions | 177.8 mm x 101.6 mm x 228.6 mm |
| Operating Temp | -20 deg C to +60 deg C |
| Power Consumption | 24 VDC nominal loop power |
| Channels | 32 isolated analog input channels |
| Signal Range | 4-20 mA (standard), 0-10 VDC (optional) |
| Resolution | 12 bits |
| Accuracy | +/-0.1% of full scale |
| Input Isolation | 2500 V RMS channel-to-channel and channel-to-backplane |
| Frequency Response | 16 Hz |
| Safety Certification | IEC 61508 SIL3, TÜV, CE, UL Class I Div 2 |
The hardware incorporates a Triple Modular Redundancy (TMR) 2oo3 architecture to execute fail-safe state execution at the input processing level. The 32 isolated analog input channels split the incoming 4-20 mA current signals into three independent legs. Each leg routes through a dedicated analog-to-digital converter (ADC) and microprocessor circuit. The field data undergoes continuous software and hardware voting before logic execution. Galvanic isolation rated at 2500 V RMS prevents electrical surges or channel-to-channel cross-talk from corrupting the separate leg processing paths. If an individual channel experiences a hardware failure, the remaining legs sustain uninterrupted voted processing while triggering internal diagnostics.
Q: How does the module execute a hot-swap sequence without corrupting live input data loops?
A: The slot architecture supports complete online hot-swapping. When you insert a replacement module into the adjacent slot on a dual baseplate, the TriBus backplane synchronization routine automatically transfers channel baseline profiles, enabling active processing without taking the safety loops offline.
Q: What are the diagnostic behaviors of the module when an open loop or wiring fault occurs?
A: The internal diagnostics run continuous background checks on loop current validity. An out-of-range signal drop below the 4 mA threshold or an open loop triggers a fault state inside the channel logs, changes the respective channel status bit, and illuminates the hardware FAULT LED.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.