100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Yokogawa AAP135-S00 S2 CENTUM VP Pulse Input / Analog Input Module

Configured for high-accuracy signal acquisition in CENTUM VP control systems, the Yokogawa AAP135-S00 S2 (AAP135 Pulse Input / Analog Input Module) provides direct physical/electrical execution across 16 channels. The hardware processes 4-20 mA DC and 1-5 V DC analog field signals alongside pulse inputs from flow meters, transmitters, and discrete field devices via the ATK4-00 S1 connector terminal assembly. Channel isolation protects local micro-controller backplane circuits against high-voltage surges and field ground potential loops. Conformal coating applied per the S2 suffix code resists chemical corrosion and moisture ingress in harsh field cabinet environments.

Suffix Breakdown & Model Matrix

Base Code Option Code Description
AAP135   Pulse Input / Analog Input Module (16-channel, CENTUM VP / CS 3000 compatible)
  -S Standard type
  0 Basic version
  0 Always 0
  S2 Conformal coating for harsh environments

Hardware Specifications

Parameter Specification
Model AAP135-S00 S2
Brand Yokogawa
Origin Japan
Weight 0.38 kg
Dimensions 130 x 120 x 30 mm
Operating Temp -20 to +55 deg C
Power Consumption 3.0 W maximum (600 mA at 5 VDC)
Input Channels 16 channels
Signal Types 4-20 mA DC, 1-5 V DC, Pulse input
Resolution 16-bit
Accuracy +/-0.1% of full scale
Signal Isolation Optical isolation per channel (1500 VAC withstand)
Input Impedance 250 ohm (current input), >250 k ohm (voltage input)
Response Time 100 ms maximum
Terminal Connection ATK4-00 S1 terminal assembly
Mounting Type Field Control Unit base plate

Process Loop & Signal Isolation Characteristics

The module incorporates 1500 VAC optical isolation per channel to integrate with 4-20 mA HART loop protocol instruments and high-speed pulse measurement circuits. Galvanic decoupling prevents ground loops from corrupting the 16-bit analog-to-digital converters during continuous scan cycles. Built-in diagnostic routines monitor power rail tolerances and signal continuity, reporting channel-level fault alarms directly to the Field Control Unit logic.

Frequently Asked Questions

Q: Can the AAP135-S00 S2 be replaced while the system rack remains energized?

A: Hot-swapping is supported. Technicians can remove and insert the module online without disrupting system logic execution or adjacent I/O modules on the backplane, provided the ATK4-00 S1 terminal block is unlatched cleanly.

Q: What environmental protection does the S2 suffix variant provide?

A: The S2 suffix indicates an industrial conformal coating applied across internal circuit assemblies. This coating guards components against corrosive gases, high relative humidity, and atmospheric particulate contamination.

Field Installation Guidelines

  1. Power down the external auxiliary field power loop before attaching or removing the ATK4-00 S1 terminal connector.
  2. Align the module card guide rails with the designated slot position on the Field Control Unit base plate.
  3. Push the card firmly into the chassis slot until top and bottom retention latches engage with a mechanical click.
  4. Fasten the ATK4-00 S1 terminal pin assembly securely to the front panel header to maintain proper contact impedance.
  5. Terminate field wiring cable shields at the cabinet grounding rail using low-impedance clamps to establish a single-point earth ground.
  6. Maintain a minimum separation clearance of 200 mm between field analog input cables and high-voltage AC power wiring.

What's clients say about us