Yokogawa ALR121-S53 S1 RS-422/RS-485 Communication Module

The Yokogawa ALR121-S53 S1, also cataloged as the ALR121 Serial Communication Module, operates as a dedicated hardware component for serial subsystem data exchange within CENTUM VP and ProSafe-RS control networks.

Suffix Breakdown & Model Matrix

Model / Suffix Code Specification
ALR121 Serial Communication Module (2-channel, RS-422/RS-485)
-S5 Standard type with basic functions
3 With diagnostic functions
S1 Hardware style code revision 1

Hardware Specifications

Parameter Specification
Model ALR121-S53 S1
Brand Yokogawa
Origin Japan
Weight 0.30 kg
Dimensions 30 mm (W) x 100 mm (H) x 80 mm (D)
Operating Temp -40 to +75 deg C
Power Consumption 0.5 A at 5 VDC (backplane bus power)
Input Voltage 24 VDC
Interface Ports 2 ports (RS-422 point-to-point / RS-485 multipoint)
Transmission Speed 1200 to 38400 bps
Max Cable Length 1200 m (RS-485) / 15 m (RS-422)
Transmission Code ASCII / Binary
Frame Synchronization Start-stop asynchronous
Isolation Barrier Photocoupler isolation between field and backplane
Module Mounting AFV30, AFV40, ANB10, ANB11 base units

Channel-to-Channel Isolation & Signal Integrity

The Yokogawa ALR121-S53 S1 incorporates photocoupler electrical isolation to decouple external field serial loops from backplane logic communication paths. Supporting Modbus slave protocols alongside customized subsystem driver configurations, the module executes half-duplex asynchronous data transfer across both independent ports. Hardware transmission buffers and dedicated signal processing circuits absorb transient common-mode voltage shifts, preventing field-side noise from interfering with controller backplane data cycles over long 1200 m RS-485 lines.

Frequently Asked Questions

Q: How are communication parameters like baud rate and parity configured on the ALR121-S53 S1?

A: Engineers configure transmission rates (up to 38400 bps), parity (None/Even/Odd), and stop bit parameters directly in the CENTUM VP software system builder, which downloads parameters to the module during initialization.

Q: Can Port 1 and Port 2 operate with different physical interfaces simultaneously?

A: Yes, each port supports independent configuration, allowing one port to run RS-422 point-to-point connections while the second port runs an RS-485 multipoint network.

Q: What cables connect field devices to the module front interface?

A: Standard Yokogawa shielded communication cables (such as the AKB131, AKB132, AKB133, and AKB134 cable assemblies) interface directly with the module's terminal blocks or connectors.

Field Installation Guidelines

Technicians should follow standard cabinet assembly procedures during field integration:

  1. Insert the module into a compatible slot on an ANB10 or ANB11 node unit after verifying backplane power keying.
  2. Terminate the RS-485 network ends using appropriate line termination resistors to eliminate signal reflection over extended cable runs.
  3. Route serial cables inside dedicated low-voltage instrument raceways, maintaining separation from high-voltage AC conductors and drive lines.
  4. Attach cable shields to the cabinet ground bar using dedicated grounding clamps to preserve noise immunity across the transmission loop.