Configured for high-density 4-20 mA analog signal acquisition in CENTUM VP and CS 3000 systems, the Yokogawa AMM25C (AMM25C Analog Input FIO Card) provides direct physical/electrical execution. This hardware component interfaces up to 32 field-side loops with the core Vnet/IP control infrastructure via internal multiplexing circuits, processing standard current signals without requiring external isolation barriers or auxiliary conversion modules.
| Parameter | Specification |
|---|---|
| Model | AMM25C |
| Brand | Yokogawa Electric Corporation |
| Origin | Japan |
| Weight | 0.5 kg |
| Dimensions | 32.8 mm x 107.5 mm x 130 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | System backplane dependent |
| Series Compatibility | CENTUM VP / CS 3000 FIO Subsystem |
| Number of Channels | 32 Channels, isolated |
| Input Signal Range | 4-20 mA DC |
| Input Resistance | 250 ohms |
| Measurement Accuracy | plus/minus 0.1 percent of full scale |
| Isolation Architecture | Galvanic isolation between field-side and system-side logic |
| Diagnostic Capabilities | Integrated open-circuit and short-circuit detection |
The module integrates a dedicated 4-20 mA HART loop protocol layer enabling seamless pass-through communication between field instruments and the CENTUM VP engineering workstation. Internal measurement nodes feature individual channel-to-channel isolation parameters to mitigate ground loop currents and prevent common-mode voltage differentials from corrupting adjacent channels. For thermal safety and accuracy across varying installation conditions, electronic temperature sensors provide automated cold junction compensation (CJC) calculation routines when processing external thermocouple signals via matching terminal boards, ensuring deterministic A/D converter scaling.
Q: Does the module support online hot-swap operations within an active FIO node?
A: Yes. The module is engineered with field-proven hot-swap logic allowing insertion and extraction under system power conditions. The backplane interface lines utilize staggered pin lengths to ensure ground connections establish first and break last, preventing transient electrical damage to system-side logic.
Q: What happens to the channel data when a field wire is severed or disconnected?
A: The module executes integrated open-circuit diagnostic logic. When the input current falls below the absolute physical threshold of 4 mA, the configuration flags register an underrange fault status bit, triggering system-side block alarms within the DCS interface.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.