100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Yokogawa ANB10D-415/CU2T Dual-Redundant ESB Bus Node Unit

The Yokogawa ANB10D-415/CU2T, also cataloged as the ANB10D Node Unit, operates as a dedicated hardware component for field I/O signal interface execution within CENTUM VP control network platforms.

Suffix Breakdown & Model Matrix

Model / Suffix / Option Code Specification
ANB10D Node Unit for Dual-Redundant ESB Bus
-4 Dual-redundant power supply configuration
1 100 to 120 VAC operational power supply
5 Basic physical hardware design without explosion protection
/CU2T Connector Unit with Terminator for ESB Bus interface

Hardware Specifications

Parameter Specification
Model ANB10D-415/CU2T
Brand Yokogawa
Origin Japan
Weight 8.0 kg
Dimensions 482.6 mm (W) x 221.5 mm (H) x 205.0 mm (D)
Operating Temp 0 to 50 deg C
Power Consumption Max 200 VA at 100 to 120 VAC
Input Voltage 100 to 120 VAC, 50/60 Hz
Bus Architecture Dual-redundant ESB bus topology
Connector Type CU2T connector unit with integrated bus terminator
Mounting Type 19-inch rack mounting
Legacy Replacement Direct replacement for ANB10D-410/CU2T

Channel-to-Channel Isolation & Signal Integrity

The Yokogawa ANB10D-415/CU2T incorporates dedicated optical and transformer isolation barriers between internal backplane logic pathways and external field I/O channels. Designed to operate within multi-drop CENTUM VP network topologies, the module leverages the dual-redundant ESB bus interface to maintain deterministic control cycles. Channel-to-channel isolation safeguards system control units against transient overvoltage spikes, ground potential offsets, and external high-frequency electromagnetic interference along field wiring runs.

Frequently Asked Questions

Q: How does the dual-redundant power supply option behave upon AC line power failure?

A: The dual internal power supply modules share system operational load concurrently; if one AC feed drops, the secondary supply maintains full module operation without backplane interruption.

Q: Is the /CU2T termination unit required on every ANB10D node slot?

A: The /CU2T termination unit attaches to the final physical node unit along an ESB bus segment to maintain bus characteristic impedance and suppress signal reflection.

Q: Can the ANB10D-415/CU2T replace older ANB10D-410/CU2T installations directly?

A: Yes, the ANB10D-415/CU2T acts as a functional and physical drop-in replacement for legacy ANB10D-410/CU2T node units.

Field Installation Guidelines

Engineers must follow these core steps when installing the ANB10D-415/CU2T node unit inside standard instrumentation enclosures:

  1. Mount the rack chassis onto standard 19-inch cabinet rails using four corner screws, ensuring at least 100 mm of open vertical space above and below for heat dissipation.
  2. Earth the system ground bus bar by running a dedicated ground wire from the chassis protective earth (PE) terminal to maintain isolation integrity.
  3. Plug both dual-redundant AC power source cables into separate circuit breakers to preserve supply redundancy.
  4. Align and lock the CU2T ESB bus interface connectors firmly, verifying that terminal block latches seat fully to prevent signal degradation.