100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

YOKOGAWA PW504 Power Supply Module

Configured for high-availability power distribution in CENTUM VP and CENTUM CS 3000 network platforms, the YOKOGAWA PW504 (PW504 Power Supply Unit) provides direct physical and electrical execution of stabilized DC voltage delivery.

Hardware Specifications

Parameter Specification
Model PW504
Brand YOKOGAWA
Origin Japan
Weight 1.5 kg
Dimensions Not specified
Operating Temp 0 deg C to +60 deg C
Power Consumption 70 W (Max output)
Output Voltage 5.1 VDC (Logic) / 24 VDC (Field)
Redundancy 1:1 Parallel

Process Control Connectivity and Isolation

The module manages power regulation within the system racks, converting wide-range AC utility input into precise DC levels required by station backplanes. The design incorporates galvanic isolation between the AC utility stage and the DC system bus to mitigate the impact of input power transients on sensitive control logic. By supporting 1:1 dual-redundant configurations, the PW504 enables parallel load sharing and ensures bumpless failover during internal component failure or upstream power loss. Furthermore, the unit features built-in protection circuitry to monitor and suppress overvoltage and overcurrent conditions, maintaining system integrity in industrial environments.

Frequently Asked Questions (FAQ)

Q: Can the PW504 be replaced while the system is powered and operational?

A: Yes, the module supports hot-swapping when deployed in a 1:1 redundant configuration. Operators must verify that the redundant partner has successfully assumed the full system load via the status LEDs before physically removing the primary unit.

Q: How does the unit handle dual-output voltage regulation?

A: The PW504 independently regulates the 5.1 VDC logic rail and the 24 VDC field rail. Internal diagnostic circuitry monitors both output rails; if a voltage deviation or thermal irregularity occurs, the module triggers the front-panel ALARM LED and signals a fault to the control system.

Field Installation Guidelines

  1. Mounting: Ensure the baseplate is secured to the cabinet rail. Insert the PW504 module into the designated slot, ensuring firm contact with the backplane connector pins. Tighten the retention screws to secure the unit against vibration.
  2. AC Input Wiring: Terminate the AC input leads according to the system wiring diagram. Use shielded cabling for AC power distribution where required to limit electromagnetic noise emission, and ensure all lines pass through appropriately rated fuses or breakers.
  3. Redundancy Configuration: When operating in a redundant pair, connect each PW504 to independent AC power feeds. This practice minimizes the risk of a total system shutdown resulting from a single circuit breaker trip or utility power loss.