Configured for stable primary electrical regulation in CENTUM VP platforms, the Yokogawa PW482-50 (PW482-50 Power Supply Unit) provides direct physical/electrical execution.
| Parameter | Specification |
|---|---|
| Model | PW482-50 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 0.80 kg |
| Dimensions | Standard FCS PSU Slot Module Dimensions |
| Operating Temp | -20 to +70 deg C |
| Power Consumption | Power supply output rated up to 5.0 A continuous at 24 VDC output |
| Style Code | Style S2 |
| Input Voltage | 100 to 240 VAC universal support, 50/60 Hz (+/- 3 Hz) |
| Output Voltage | 24 VDC nominal regulated |
| Redundancy | 1:1 dual-redundant pair support |
| Isolation Resistance | Minimum 100 Mohm at 500 VDC |
| Withstanding Voltage | 1500 VAC between input and output/ground |
| Protection Logic | Overvoltage, overcurrent, short-circuit, and thermal shutdown |
The PW482-50 power module routes regulated 24 VDC power across internal backplane buses while isolating field instrumentation power from main control processors. Internal monitoring circuits report power health metrics to the central system processor over Vnet/IP lines, maintaining continuous operation alongside field devices utilizing the 4-20 mA HART loop protocol and isolated channel-to-channel I/O setups with automated cold junction compensation (CJC).
Q: Can the PW482-50 power supply module be replaced while the Field Control Station remains operational?
A: Yes. In a 1:1 dual-redundant power configuration, a faulty PW482-50 unit can be extracted and swapped under live AC power without dropping the 24 VDC bus output or disrupting active DCS control processes.
Q: What protective measures prevent power surges from damaging internal FCS backplane logic?
A: The PW482-50 integrates automatic overvoltage, overcurrent, and thermal protection circuits, along with an isolation rating of 1500 VAC between input terminals and internal backplane logic.
Mount the power module securely into the designated Field Control Station power slot until the locking levers latch completely. Connect the AC mains input wiring using proper wire gauge sizes and verify input voltage stays within the 100 to 240 VAC operating window. Ensure dedicated protective earth grounding cables connect firmly to system ground points to minimize electrical noise and transient surges. Maintain proper panel ventilation clearance around the module chassis to facilitate convection heat dissipation during maximum 5.0 A load operation.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.