100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Yokogawa SSC60D-F2541 Safety Control Unit

The Yokogawa SSC60D-F2541, also cataloged as the SSC60D Duplexed Safety Control Unit, operates as a dedicated hardware component for SIL3-certified safety logic execution within ProSafe-RS Safety Instrumented Systems. Configured with dual-redundant CPU architecture and dual Vnet/IP communication interfaces, the unit executes deterministic 100 ms safety cycles and fail-safe diagnostic routines inside Safety Control Stations (SCS). Dual ESB bus integration maintains continuous data processing to bring processes to a defined safe state during Emergency Shutdown (ESD) or Fire & Gas (FGS) events.

Suffix Breakdown & Model Matrix

Suffix Code Option Specification
-F High-capacity F-type duplexed variant
2 Dual-redundant power supply
5 Basic type with no explosion protection
4 220-240 V AC power supply input
1 Standard system platform license configuration

Hardware Specifications

Parameter Specification
Model SSC60D-F2541
Brand Yokogawa
Origin Japan
Weight 8.5 kg to 13.0 kg (Shipping weight: 10.0 kg to 15.0 kg)
Dimensions 482.6 mm x 266 mm x 88.1 mm (19-inch rack unit)
Operating Temp -20 deg C to +70 deg C
Power Consumption 200-290 VA for AC models (320 W max load / 5.5-7.0 A for DC models)
Safety Integrity Level SIL3 compliant
Architecture Dual-redundant CPUs with ECC-protected RAM and battery backup
Network Interfaces Dual Vnet/IP (100 Mbps full duplex, RJ45) and dual ESB bus
Logic Execution Cycle 100 ms
I/O Expansion Capacity Up to 8 modules per SCU; up to 110 modules across 13 node units
Protection Rating IP66 front panel protection

SIL3 Certification & Fail-Safe State Execution

The SSC60D-F2541 utilizes a redundant 2oo3 internal processor voting structure and dual communication channels to comply with SIL3 safety loop standards. Galvanic isolation barriers protect internal microprocessors from field wiring fault transients. Integrated online diagnostic routines continually verify memory matrix integrity and peripheral logic paths; if an unrecoverable hardware fault occurs, the module forces system outputs into a predefined fail-safe shutdown state.

Frequently Asked Questions

Q: How does the dual Vnet/IP network interface execute fault tolerance on the SSC60D-F2541?

A: The control unit runs simultaneous communication over dual redundant 100 Mbps Ethernet buses (RJ45 CAT5e), seamlessly shifting control traffic to the secondary bus if a cable or port failure occurs.

Q: What power input ranges does the SSC60D-F2541 support?

A: Depending on the specific suffix selection, the unit accommodates dual 100-120 V AC, 220-240 V AC, or dual 24 V DC redundant power inputs.

Field Installation Guidelines

Mount the SSC60D-F2541 horizontally into a standard 19-inch cabinet frame within the Safety Control Station enclosure. Secure the chassis with four front panel mounting screws to establish physical stability and earth ground grounding through the rack frame.

Connect dual independent primary power lines to the rear AC/DC input terminals to ensure power supply redundancy. Plug category 5e (or higher) Ethernet cables into the primary and secondary Vnet/IP ports. Ensure a dedicated single-point earth grounding strap is fastened to the chassis ground terminal to mitigate electromagnetic interference and maintain SIL3 system compliance.