The Allen-Bradley 1492-CABLE010X functions as a high-reliability bridge between ControlLogix 1756 I/O modules and Interface Modules (IFMs). This pre-wired cordset eliminates the labor-intensive process of manual point-to-point wiring, which often introduces human error and increases commissioning time. By utilizing factory-tested connections, this cable ensures signal integrity across 20 distinct conductors. We offer this product as 100% Brand New and Original, ready for immediate deployment in mission-critical automation panels.
The following parameters define the electrical and mechanical limits of the 1492-CABLE010X cordset.
| Attribute | Specification Details |
| Catalog Number | 1492-CABLE010X |
| Length | 1.0 Meter (3.28 Feet) |
| Conductor Count | 20 Conductors |
| Wire Gauge | 22 AWG |
| Module Connector | 1756-TBNH (20-Position) |
| IFM Connector | 20-Pin Fixed Interface Connector |
| Compatibility | Standard 1756 16-Point I/O Modules |
| Jacket Material | Industrial Grade PVC |
| Operating Temp | -20 to 75 C |
| Voltage Rating | 300V AC/DC |
Error-Free Commissioning: The factory-molded 1756-TBNH connector snaps directly into your ControlLogix module. This prevents miswiring incidents that can lead to short circuits or damaged I/O points during the initial power-up phase.
Reduced Panel Footprint: The organized, bundled 22 AWG conductors maintain a slim profile compared to 20 individual wires. This design optimizes airflow within the cabinet and allows for cleaner cable tray management in dense 1756 racks.
Vibration Resistance: Pre-wired connectors provide superior mechanical stability over hand-tightened screw terminals. The industrial-grade PVC jacket protects internal conductors from chemical exposure and mechanical abrasion common in manufacturing environments.
Rapid Replacement: In maintenance scenarios, technicians can swap a faulty I/O module or IFM in seconds by disconnecting the specialized plugs, drastically reducing Mean Time to Repair (MTTR).
Q: Which specific PLC modules does this cable support?
A: This cable specifically supports standard Allen-Bradley 1756 ControlLogix 16-point digital I/O modules that utilize the 1756-TBNH (removable terminal block) interface. It is not compatible with high-density 32-point modules or those requiring a 1756-TBCH connector.
Q: Can I modify the length of this cable in the field?
A: No. The 1492-CABLE010X is a factory-sealed, pre-terminated unit. Cutting or splicing the cable compromises the factory testing and the UL/CSA certifications. If your layout requires a different distance, you should select the 0.5m, 2.5m, or 5.0m variants of the 1492-CABLE series.
Q: How does the "X" suffix in the part number affect usage?
A: The "X" denotes the specific connector orientation and wiring pinout designed for 16-point digital modules. This ensures the 20 conductors (including power and common) align perfectly with the standard 1492 Interface Modules.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.