The Yokogawa F3XD32-3F, also cataloged as the F3XD32 Digital Input Module, operates as a dedicated hardware component for high-speed acquisition of discrete 24 V DC signals within FA-M3 PLC platforms. The hardware processes multi-channel state execution from field sensors, switches, and relays using a bi-directional sink/source compatible circuit configuration. It utilizes phototransistor arrays to maintain electrical isolation between the field wiring loops and the internal logic backplane.
| Parameter | Specification |
|---|---|
| Model | F3XD32-3F |
| Brand | Yokogawa |
| Platform | FA-M3 PLC series |
| Origin | Japan |
| Weight | 0.25 lbs (115 g) |
| Dimensions | 28.9 x 100 x 83.2 mm |
| Operating Temp | -10 to +55 deg C |
| Power Consumption | 110 mA maximum at 5 V DC |
| Input Points | 32 channels |
| Input Configuration | Sink/Source compatible |
| Rated Input Voltage | 24 V DC |
| Operating Voltage Range | 20.4 to 26.4 V DC |
| Input Current | 4.1 mA per channel |
| ON Condition | 16.0 V DC minimum, 3.2 mA minimum |
| OFF Condition | 5.8 V DC maximum, 0.9 mA maximum |
| Response Time | 0.1 ms maximum (configurable filter: 0 us, 62.5 us, 250 us, 1 ms, 16 ms) |
| Isolation Method | Photocoupler isolation |
| Common Architecture | 8 points per common line |
| Connection Type | 40-pin high-density connector |
The hardware features robust channel-to-channel isolation metrics achieved via its internal optocoupler network, protecting the central processor from external electrical transients. Field signals interface through configuration registers that allow independent digital filtering to eliminate contact bounce and electromagnetic noise. In distributed process control structures, this architecture matches the high-frequency sampling demands of 4-20 mA HART loop protocol diagnostic status signals. The logic processing framework maps discrete state transitions directly to the internal registers, ensuring synchronous execution alongside cold junction compensation units in hybrid DCS systems.
Q: Does this module support hot-swapping while the base unit is energized?
A: No. Power to the FA-M3 base unit must be completely disconnected before removing or inserting the module to prevent electrical damage to the backplane communication pins.
Q: How is the default hardware response time modified?
A: The response time is modified via the PLC CPU configuration software, allowing the input filter to adjust between 0 us for high-speed pulse inputs and up to 16 ms for high-noise environments.
Q: Can both sink and source devices be connected to the module simultaneously?
A: No. While the module supports both configurations, the wiring type is determined per common group of 8 points. All 8 points sharing a common line must share the same reference polarity.