Configured for process monitoring and alarm signaling in DCS and SCADA networks, the Yokogawa UM33A-000-11/LP (UM33A Digital Indicator with Alarms) provides direct physical/electrical execution. The panel-mounted hardware accepts universal analog input signals, processing thermocouple, RTD, DC millivolt, voltage, and 4-20 mA current loops at a scan rate of up to 50 ms with an indication accuracy of +/-0.1% of full scale.
| Suffix / Option Code | Option Specification |
|---|---|
| Basic: 0 | Standard type |
| Functions: 0 | None |
| Open networks: 0 | None |
| Display language: 1 | English (Default, switchable via parameter settings) |
| Case colour: 1 | Black (Light charcoal gray) |
| /LP | 24 VDC loop power supply option |
| Parameter | Specification |
|---|---|
| Model | UM33A-000-11/LP |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | Max 0.5 kg (Shipping weight: 1.5 kg) |
| Dimensions | 96 mm (W) x 48 mm (H) x 65 mm (D panel depth); Panel cutout: 92 mm x 45 mm |
| Operating Temp | 5 deg C to 40 deg C |
| Power Consumption | Max 15 VA (100-240 VAC supply or optional 24 VAC/DC) |
| Input Signals | Universal input: Thermocouple (TC), RTD, mV, V, mA |
| Measurement Accuracy | +/-0.1% of full scale |
| Control Scan Period | 50 ms, 100 ms, or 200 ms |
| Display Type | 14-segment, 5-digit color LCD |
| Digital Inputs | 2 points (no-voltage contact or transistor contact for PV peak/bottom reset) |
| Relay / Alarm Outputs | 3 standard relay outputs (1a), up to 9 max (including Alarm-4 1c contact) |
| Retransmission Output | 1 point (4-20 mA DC or 0-20 mA DC, max 600 ohm load) shared with 15 VDC supply |
| Protection Rating | NEMA4 / IP66 front panel protection |
The UM33A-000-11 digitizes analog process inputs across field-mounted transmitters operating on 4-20 mA HART loop protocol lines. Internal signal processing features polygonal line approximation and bias corrections to preserve measurement accuracy. Thermocouple sensor inputs rely on precise internal cold junction compensation (CJC) circuits to prevent temperature measurement drift caused by ambient terminal fluctuations.
Q: What termination hardware does the UM33A-000-11 use for field signal connections?
A: Terminal connections utilize M3 screw terminals fitted with square washers to secure signal conductors and primary AC/DC power wiring.
Q: What are the physical mounting orientation restrictions for the panel housing?
A: Install the unit upright or tilted up to 30 degrees above the horizontal plane; downward tilting is strictly prohibited.
Prepare a 1/8 DIN panel cutout measuring 92 mm by 45 mm. Insert the UM33A-000-11 housing from the front of the control panel, ensuring the gasket seals tightly against the panel face to maintain its NEMA4/IP66 ingress protection rating.
Secure the instrument using the supplied side mounting brackets. Fasten signal and power conductors to the rear M3 screw terminals using standard spade or ring lugs. Maintain separate cable trays for low-level analog input wiring and high-voltage power lines to prevent electromagnetic noise coupling. Verify ground wire continuity to the earth ground terminal prior to energizing the 100-240 VAC main supply.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.