The Woodward 8200-226, also cataloged as the 8200-226 Servo Position Controller / Actuator Driver, operates as a dedicated hardware component for converting low-level control signals into high-current bipolar drive outputs within turbine and reciprocating engine control networks.
| Parameter | Specification |
|---|---|
| Model | 8200-226 |
| Brand | Woodward |
| Origin | USA |
| Weight | 1.55 kg |
| Dimensions | 32.9 cm x 20.3 cm x 6.5 cm |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | 20 W Typical at full load |
| Input Power | 18-32 VDC (Nominal 24 VDC) |
| Output Current Range | +/-10 mA to +/-250 mA (Bipolar, Software Configurable) |
| Control Signals | 4-20 mA, 1-5 VDC, or Pulse Width Modulation (PWM) |
| Input Impedance | 200 ohm |
| Control Resolution | 11-bit positioning |
| Operating Range | 2-22 mA (Signal Input) |
| Protection Circuitry | Overvoltage, Reverse Polarity, and Short-Circuit Protection |
Operating within high-performance prime mover control systems, this unit relies on specialized actuator loop feedback response metrics to interface between electronic governors and hydraulic or pneumatic actuators with sub-millisecond latency. The board regulates internal power distribution to handle thermal heat sink dissipation profiles generated during high-load bipolar operations up to +/-250 mA. The internal digital processing architecture converts input demands via an 11-bit high-definition positioning matrix, eliminating calibration drift linked to component aging, and matches the driving profiles required by the Woodward 512 and 8256 series proportional actuators.
Q: How does the 8200-226 module handle a sudden short-circuit condition within the external actuator coils?
A: The module relies on integrated hardware protection circuitry that immediately clamps the output loop to prevent damage, while concurrently registering a diagnostic fault signal back to the main electronic governor.
Q: Is the bipolar output current fixed, or can it be adjusted for smaller servo valves?
A: The output current is software configurable from +/-10 mA up to +/-250 mA, allowing engineers to calibrate the driver output to match the precise electrical parameters of the target actuator.
Q: What legacy Woodward modules does the 8200-226 directly replace?
A: This model serves as the official digital upgrade path for the legacy analog 8200-224 and 8200-225 driver boards.
Mount the 8200-226 assembly securely inside the control enclosure, ensuring proper clearance around the integrated thermal heat sink structures to support unimpeded air dissipation. Before connecting the 18-32 VDC primary input power, verify that the power supply polarity matches the driver terminal block layout. Connect all analog demand signals (such as 4-20 mA or 1-5 VDC) and bipolar actuator drive loops using individual shielded twisted-pair cables. Terminate the shield drain wires at the designated enclosure chassis ground rail to prevent stray electromagnetic interference from degrading the 11-bit control resolution.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.