Configured for high-speed signal conversion in CENTUM VP platforms, the Yokogawa SAI143-H63/PRP S3 (SAI143-H63 Analog Input Module) provides direct physical/electrical execution for 16-channel transmitter loops.
The suffix designations detail protocol configurations and environmental ratings for the SAI143 hardware platform:
| Parameter | Specification |
|---|---|
| Model | SAI143-H63/PRP S3 |
| Brand | Yokogawa Electric Corporation |
| Origin | Japan / Singapore |
| Weight | 0.81 kg |
| Dimensions | 130 x 45 x 245 mm |
| Operating Temp | -20 deg C to +70 deg C |
| Power Consumption | 320 mA at 5 VDC, 550 mA at 24 VDC |
| Input Channels | 16 channels, module-isolated |
| Signal Range | 4 to 20 mA DC (permissible 0 to 25 mA DC) |
| Conversion Performance | 16-bit A/D resolution, 40 ms data update cycle |
| Accuracy | +/-16 uA over 0.05 to 23 mA input range |
| Signal-to-System Isolation | 1.5 kV AC for 1 minute |
The SAI143-H63 module processes analog field signals using a 16-bit A/D converter, refreshing all 16 channels every 40 ms. Built-in HART pass-through capabilities allow simultaneous transmission of 4-20 mA HART loop protocol variables and digital diagnostic data to central management software. Module-to-system galvanic isolation withstands up to 1.5 kV AC, protecting internal backplane logic against common-mode noise, ground loops, and field voltage surges.
Q: Does the SAI143-H63 module provide field power for 2-wire transmitters?
A: Yes. The module features an integrated transmitter power supply function providing 16.15 to 26.4 VDC (current-limited to 25 mA) selectable across all 16 channels simultaneously for 2-wire loop configurations.
Q: How does the /PRP option affect network communication behavior during a line failure?
A: The Parallel Redundancy Protocol (/PRP) option transmits duplicate Ethernet packets over two independent networks simultaneously. If one network path fails, the destination node receives the packet via the secondary path with zero failover latency.
Mount the SAI143-H63 module vertically into the dedicated rack slot, securing the upper and lower panel thumbscrews to establish proper chassis grounding. Verify that field wiring connections to the 16-channel terminal block are tight, maintaining separated routing for signal cables and high-voltage power lines. Ensure the backplane power supply is switched off before inserting or removing the terminal block to prevent unexpected arc discharges or signal disruptions.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.