Configured for simultaneous analog signal processing and current output generation in VersaMax system platforms, the GE Fanuc IC200ALG430 (IC200ALG430 Analog Combination Module) provides direct physical/electrical execution. The module integrates 4 differential 4-20 mA input channels and 2 single-ended 4-20 mA current outputs, converting signals with 12-bit digital resolution across all channels.
| Parameter | Specification |
|---|---|
| Model | IC200ALG430 |
| Brand | GE Fanuc |
| Origin | USA |
| Weight | 0.38 lbs (0.17 kg) |
| Dimensions | Single-slot VersaMax module footprint |
| Operating Temp | 0 deg C to 60 deg C |
| Power Consumption | 50 mA at 5 VDC (backplane bus); 215 mA max plus load currents (external) |
| Analog Inputs | 4 differential channels (4-20 mA) |
| Analog Outputs | 2 single-ended channels (4-20 mA) |
| Resolution | 12-bit (inputs and outputs) |
| Input Update Rate | 0.4 ms maximum |
| Output Update Rate | 0.3 ms maximum |
| Input Filter Response Time | 5.0 ms |
| External Power Supply | +18 to +30 VDC or 9.6 to 15 VDC (required for output circuits) |
| Isolation | 250 VAC continuous, 1500 VAC for 1 minute (optical) |
| Crosstalk Rejection | 30 dB minimum channel-to-channel |
| Status Indicators | 2 LEDs (FLD POWER, MODULE OK) |
The module transmits 4 words of input data and receives 2 words of output data across the VersaMax backplane bus, drawing 50 mA maximum at 5 VDC logic power. Internal Analog-to-Digital (ADC) circuits process analog input updates every 0.4 ms, while output loops update within 0.3 ms. Compatibility and default input state selection depend on CPU/NIU firmware versions; when paired with CPU or NIU version 1.5 or later, input default behavior aligns with the jumper-defined output default configuration.
Q: Does the IC200ALG430 require external field power to process input channels?
A: No, input processing circuits operate solely on logic power provided by the backplane bus. External 12 VDC or 24 VDC power is required exclusively for the analog output current loops.
Q: What status indicators are available on the module front panel?
A: The module includes a MODULE OK LED to signal backplane power initialization and a FLD POWER LED to confirm external field voltage presence.
Q: What occurs if user-side field power is lost during operation?
A: Onboard diagnostic tools detect the loss of user-side power and report the fault condition to the central controller.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.