The UR8HH (Model: UR8HH) is a high-density, multifunctional expansion module designed for the GE Multilin Universal Relay (UR) series. This module acts as a critical hybrid interface, integrating analog Current Transformer (CT) acquisition with high-capacity digital inputs and outputs. The UR8HH (Part Number: UR-8HH) is specifically engineered for utility-scale protection schemes, allowing a single chassis slot to manage phase/ground current sensing alongside auxiliary breaker control and status monitoring.
Built for the rigorous transients of substation environments, the UR8HH (Model: UR8HH) features 16 optically isolated digital inputs and 8 Form-C relay outputs. This consolidated architecture enables the protective relay to execute sub-cycle trip commands while maintaining real-time awareness of field contact states. The module's utility-hardened design ensures electromagnetic compatibility and reliable performance in mission-critical grid infrastructure.
The UR8HH module integrates analog sensing and digital logic into a 6U modular footprint:
Manufacturer: GE Multilin (General Electric)
Model Number: UR8HH
Part Number: UR-8HH
Series: Universal Relay (UR) Series (B30, C30, D60, G60, L90, etc.)
Module Type: Combined CT/VT and Digital I/O
Phase CT Inputs: 3 Channels (Supports 1A or 5A nominal, software-selectable)
Ground CT Inputs: 1 Channel (Supports 1A or 5A nominal)
Digital Inputs: 16 Optically Isolated channels
Input Voltage Range: 24V to 250V DC (Wide range threshold)
Relay Outputs: 8 Form-C (Normally Open/Normally Closed)
Output Contact Rating: 10A at 250 VAC / 30 VDC
Dielectric Strength: 2kV AC for 1 minute (I/O to Ground)
Operating Temperature: –40°C to +85°C (Industrial Grade)
Diagnostics: Integrated LEDs for channel status and module health
Dimensions: 170 mm x 105 mm x 32 mm (Standard 6U UR Slot)
Weight: 2.27 kg (5.00 lbs)
The UR8HH (Part Number: UR-8HH) is typically deployed in the following power system protection roles:
Feeder Protection: Measuring phase currents while providing ample I/O for breaker interlocking and trip/close coils.
Transformer Monitoring: Managing CT inputs for differential protection zones and monitoring tank pressure/temperature via digital inputs.
Breaker Control: Serving as a high-density I/O interface for dual-breaker configurations within a single relay.
Bus Protection: Providing the necessary CT sensing and lockout relay outputs for busbar protection schemes.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.